This paper presents the results of seven experimental tests in reinforced concrete wide beams, aiming to investigate their performance when subjected to shear, using prefabricated truss stirrups as shear reinforcement, as well as a supplementary reinforcement to control cracks by delamination. The main analysed variables were: position of the supplementary reinforcement, inclination of the shear reinforcement, and spacing between stirrups. Results showed that strength increments of up to 142% were obtained using the prefabricated truss stirrups. Furthermore, the experimental results were compared with the theoretical shear strength estimates of the tested beams, following the recommendations of NBR 6118 (2014), Eurocode 2 (2004), and ACI 318 (2014), in order to evaluate the safety level of these codes when designing concrete elements subjected to shear with the reinforcement used in this paper.
ResumoThis paper presents the results from a parametric study carried in order to quantify how far errors in the design stage related to the consideration of the wind action may put at risk the response and safety of reinforced concrete buildings. Using an architectural model as reference and varying the number of floors of the building, the structural safety was evaluated as a function of the wind action intensity. Results showed that even for low-rise buildings, with 10 floors, ignoring the wind action can significantly jeopardize their behaviour and safety. Yet, for slenderer buildings, up to 30 floors, it can lead to catastrophic results, as the ruin of the structure by progressive collapse.Keywords: wind, columns, reinforced concrete, buildings.Este artigo apresenta os resultados de um estudo paramétrico realizado com o objetivo de quantificar o tanto que erros na etapa de projeto relacionados com a consideração da ação do vento podem comprometer a resposta em serviço e a segurança de edifícios de concreto armado. Usando-se um modelo arquitetônico como referência e variando-se o número de pavimentos do edifício, a segurança estrutural foi avaliada como uma função da intensidade da ação do vento. Os resultados mostraram que mesmo para edifícios baixos, com 10 pavimentos, a desconsideração da ação do vento pode comprometer significativamente o comportamento e a segurança e que no caso de edifícios mais esbeltos, com até 30 pavimentos, pode levar a resultados catastróficos, como a ruína da estrutura através de colapso progressivo.Palavras-chave: vento, pilares, concreto armado, edifícios.
PBuscando avaliar a influência da ancoragem na resistência à flexão de vigas reforçadas com mantas de Polímero Reforçado com Fibra de Carbono (PRFC), foram analisados os resultados experimentais de 126 ensaios presentes na literatura e de uma série inédita, ensaiada pelos autores, com 4 vigas de concreto armado. São avaliados os parâmetros que afetam o desempenho e a resistência das vigas, e discutidos os critérios de dimensionamento do fib Bulletin 14 (2001) e ACI 440-2R (2008). Observou-se que, mesmo com dispositivos auxiliares na ancoragem do PRFC, falhas prematuras são possíveis, e também que ambas as recomendações teóricas conduzem a estimativas a favor da segurança, porém excessivamente conservadoras nos casos onde a ancoragem da manta de PRFC é feita adequadamente.
The use of column capitals is one way to increase the punching strength of slab-column connections. Recommendations presented by codes of practice for defining the geometry and checking the resistance of slab-column connections with capitals are not comprehensive, with few experimental studies available on the topic. This paper discusses important aspects of the historical development of mushroom slabs and also presents experimental results of 4 tests, with 1 test in a reference flat slab and 3 tests in mushroom slabs with circular column capitals. These results are compared with theoretical results estimated using Eurocode 2 (2004) and NBR 6118 (2007). They were also compared with a series of non-linear finite element analysis in order to get insight of the stress distribution and of the failure mechanism of mushroom slabs.Keywords: mushroom slab, punching shear, reinforced concrete, column capitals.O uso de capitéis é uma das formas de se aumentar a resistência à punção de ligações laje-pilar. As recomendações normativas para a definição da geometria e verificação da resistência última de ligações com capitéis são pouco abrangentes, sendo poucas as pesquisas experimentais disponíveis sobre o tema. Este artigo discute aspectos relevantes do desenvolvimento histórico das lajes cogumelo e apresenta resultados de 4 ensaios experimentais, sendo 1 laje lisa de referência e 3 lajes cogumelo com capitéis de seção circular. Estes resultados são comparados com as estimativas das normas EUROCODE 2 (2004) e NBR 6118 (2007) e com modelos numéricos não-lineares a fim de se compreender melhor a distribuição das tensões e o mecanismo de ruptura de lajes cogumelo.Palavras-chave: lajes cogumelo, punção, concreto armado, capitel. Experimental and numerical analysis of reinforced concrete mushroom slabsAnálise experimental e numérica de lajes cogumelo de concreto armado Faculdade de Engenharia Civil, Universidade Federal do Pará, Campus de Tucurui, aaraon@ufpa.br, Tucurui, Pará, Brasil. b Professor, Faculdade de Engenharia Civil, Universidade Federal do Pará, mpina@ufpa.br, Belém, Pará, Brasil. c Professor, Faculdade de Engenharia Civil, Universidade Federal do Pará, denio@ufpa.br, Belém, Pará, Brasil. d Professor, Departamento de Engenharia Civil e Ambiental, Universidade de Brasília, melog@unb.br, Brasília, Distrito Federal, Brasil. Received: 06 Jun 2012 • Accepted: 12 Nov 2012 • Available Online: 05 Apr 2013 Abstract Resumo
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.