Abstract. A digital recording system has been operated at the U.K. observatories since 1979. The magnetic elements H, D, and Z are monitored continuously by a triaxial fluxgate magnetometer operating in the variometer mode, Ordinate values are recorded at 30-sec intervals. Total field and the temperature of the variometer chamber are measured at the start of each 10-rain data block.Fluxgate magnetometer baseline values are derived from absolute measurements made by proton vector magnetometer and Kew declinometer in the conventional manner.In this paper the data handling procedures are described and the quality of the data over a period of two years is discussed,
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.