In this paper, the flow field inside a square channel with a two-stage electrohydrodynamic (EHD) gas pump has been critically examined by experimental measurement and numerical simulation. The EHD gas pump with 28 emitting electrodes in each stage is tested for a wide range of operating voltages starting from the corona onset voltage up to 28 kV for further improvement in its performance over a single-stage one. It has been shown that the two-stage EHD gas pump can produce and sustain gas flows with a maximum velocity of 1.8 m/s. Its maximum performance of 36 L/s/W is better than that of conventional cooling fans used in personal computers. The implication for its application in thermal management and heat transfer enhancement has also been discussed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.