The end-tidal carbon dioxide (CO2) concentration has been found to correlate with cardiac output during and after cardiopulmonary resuscitation (CPR) in animal models. We monitored end-tidal CO2 values continuously during cardiac resuscitation in 23 humans while ventilation was held constant with a computer-controlled CPR Thumper. This report focuses on ten of the 23 patients who experienced return of spontaneous circulation (ROSC) during monitoring. There was no significant difference in the end-tidal CO2 value of patients without ROSC (1.8% +/- 0.9%) and the end-tidal CO2 value of patients before ROSC in patients who had ROSC (1.7% +/- 0.6%). The end-tidal CO2 concentration increased immediately in all patients who had ROSC, from 1.7% +/- 0.6% to 4.6% +/- 1.4%, then gradually returned to a new baseline (3.1% +/- 0.9%). Change in the end-tidal CO2 value was often the first clinical indicator that ROSC had occurred. Our findings suggest that end-tidal CO2 monitoring may provide clinically useful information that can be used to guide therapy during CPR.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.