Abstract-The Western Link is a new point-to-point embedded HVDC connection due to be commissioned in Great Britain in 2018. This paper investigates the optimal loading of the Western Link with respect to the wider transmission system. The work modelled a representation of behaviour of the wholesale market and system operator actions using mathematical optimisation in the form of an economic dispatch followed by an AC optimal power flow. A range of different system cases was studied using: a representative high voltage transmission network of Great Britain; system planned outages on AC circuits in parallel with the Western Link; system contingencies; and two possible post-contingency Western Link loading rules. It was concluded from the cases studied that the optimal dispatch of power on the Western Link is an affine function of power flow in the parallel AC circuits, modulated by system planned outages and the thermal rating of the Western Link.
This paper proposes the use of surrogate model optimisation methods to solve box constrained LCC-HVDC controller tuning problems. The tuning problem is the selection of the proportional-integral controller gains and voltage-dependant current order limiter parameters of an LCC-HVDC link subject to two operational scenarios and a set of large-signal disturbances. The solvers using recently proposed surrogate model methods performed either similarly to or significantly better than solvers using mature methods of the types found in PSCAD/EMTDC, thus confirming the suitability of these surrogate model solvers for simulation-based optimisation of LCC-HVDC controllers.
Cascading failures of relay operations in power systems are inherently linked with the propagation of widearea power system blackouts. In this paper, we consider a power system cascading failure as an indicator matrix encoding: what power system relays operated within a cascading failure inherently capturing the component and the sequence of tripping events. We propose that this matrix may then be used with extended forms of variance-based sensitivity estimators to quantitatively rank how sensitive observed power system cascading failures are to power system variables, considering overall system cascading failures as well as cascading failures grouped by network area and relay types. We demonstrate our proposed method by investigating the sensitivity of cascading failures to relay parameters, system conditions, and fault location using a version of the IEEE 39 bus model modified to include protection relays, wind farms, and tap-changing transformers. Input power system variables included: system operational scenario, disturbance location, relay parameters or thresholds. The Case Studies' results confirm the method's utility by successfully generating relative rankings of input variables' importance with respect to cascading failure propagation. The results also show cascading failures' sensitivity to input variables to be high due to non-linear relationships between input variables and cascading failures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.