Sedimentation by gravity is the oldest water treatment. Inlet and outlet of rectangular sedimentation tank are often located in the middle of the tank. The present investigation studies the effect of changing inlet and outlet position of rectangular sedimentation tank on removal efficiency using Computational Fluid Dynamics method. Two different configurations are proposed and they have been tested with varying particles diameters and concentration. Numerical model ability to describe flow field behaviour inside the tank is confirmed by an experimentation data. Results show that inlet and outlet position influence the flow field and removal efficiency of sedimentation tanks, especially for the case of fine particles (50 and 120µm).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.