Plate bending structural stiffness and strength can be most effectively enhanced by using a larger sized plate, but gains can also be achieved by using a thicker plate and/or an LC-DCP instead of a DCP implant when possible.
A CBS screw placed in lag fashion provides stiffer fixation than an HCS screw, although both screws provide similar anatomical reduction and yield strength to condylar fracture fixation in adult canine humeri.
The dogs of this report developed hydrocarbon pneumonitis following exposure to waterproofing sprays. Such sprays contain potentially toxic hydrocarbons. The severity of the adverse effects associated with exposure may have been amplified because the dogs were physically small and were exposed to a relatively large amount of aerosolized spray within small areas. Development of chemical pneumonitis in pet animals is best prevented by application of waterproofing sprays in well-ventilated or outdoor areas from which pets have been excluded. With prolonged hospitalization and considerable monitoring and care, affected dogs can recover from these exposures.
Retrospective evaluation of repairing distal radial and ulnar fractures in small breed dogs with the Synthes 1.5-mm locking Adaption plate system and compare results in a similar group of patients repaired with the Synthes 2.0-mm limited contact-dynamic compression plate (LC-DCP). Electronic medical records from one specialty referral centre were reviewed from March 21, 2010, to October 9, 2015, for patients weighing less than or equal to 4 kg that had a distal one-third radial and ulnar fracture repaired with a Synthes 1.5-mm locking adaption plate or Synthes 2.0-mm LC-DCP. Further inclusion criteria included application of the plate to the cranial surface of the radius via open reduction and internal fixation. Six 1.5-mm Adaption plates and 7 2.0-mm LC-DCPs were used to repair 13 distal radial and ulnar fractures in 12 dogs. There were three major complications in the 1.5-mm adaption plate group (one plate fracture, one screw pull-out and one fracture through a distal screw hole) and one major complication in the 2.0-mm LC-DCP group due to a re-fracture. All patients without a complication had good or excellent functional outcome. The authors recommend that the 1.5-mm Adaption plate be used only when a 2.0-mm LC-DCP would not allow for a minimum of two screws in the distal segment and at the discretion of the surgeon.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.