The proposed digital parity generator circuit is an integrated circuit functions to detect data errors at the transmitter end, and check it at the receiving end. In digital communications, the digital messages are transmitted in the form of 1’s and 0’s between two points. It is an error free if both are the same. The purpose of this research is to implement a design method of digital parity generator layout with 0.7 micron process technology ECPD07 from Tanner Tools. Layout design starts from making schematic circuit, test function and make a layout. Next, check the layout results in terms of design rules and verify the desired functionality gradually. The results show that the circuit has functioned well as an odd parity generator. The simulation results obtained with loads CL = 25 fF, tpLH = 2nS and tpHL = 1.46 nS indicate that tp = 1.73nS or operating frequency of 578 MHz. The integrated digital parity generator circuit using transmission gate has a size of 14758 um2 (78.5 um x188 um), consisting of 74 gates.<br /><br />
Penggunaan energi listrik di gedung-gedung pemerintahan terkesan kurang memperhatikan ketentuan penghematan energi listrik. Pada kenyataannya, banyak ruangan yang masih menyalakan lampu penerangan pada siang hari meskipun pencahayaan ruangan sudah cukup terpenuhi oleh sinar matahari. Penggunaan air conditioner (AC) banyak yang tidak sesuai dengan volume ruangan dan jumlah orang yang beraktivitas dalam ruangan tersebut. Hal ini menyebabkan terjadinya pemborosan energi listrik. Universitas Negeri Gorontalo (UNG) mempunyai permasalahan dalam pemborosan energi listrik. Berdasarkan data dari bagian rumah tangga UNG, penggunaan daya listrik bulan Maret 2021 adalah 65.291.330 VA. Hal tersebut sangat membebani anggaran biaya operasional universitas (±60,30% dari dana operasional rumah tangga UNG). Tujuan penelitian ini adalah menganalisis intensitas penggunaan energi listrik dan menetapkan kebijakan penghematan penggunaan energi listrik. Studi penelitian dilakukan di Fakultas Teknik UNG. Metode penelitian yang digunakan adalah metode analisis audit intensitas konsumsi energi (IKE). Tingkat pencahayaan ruangan sesuai cahaya lampu penerangan dan cahaya matahari yang masuk dalam ruangan diukur secara langsung dengan lux meter dan dianalisis sesuai ketentuan Standar Nasional Indonesia (SNI) 6197-2011. Penggunaan energi listrik pada ruangan ber-AC maupun tidak ber-AC dianalisis menggunakan metode analisis IKE. Tingkat penggunaan energis mengacu pada standar efisiensi sesuai Peraturan Menteri ESDM No. 13 Tahun 2012. Hasil penelitian menunjukkan bahwa rata-rata 23,43% dari 233 ruangan memiliki intensitas pencahayaan melebihi standar SNI. Penggunaan daya listrik pada ruangan ber-AC selama satu bulan (26 hari kerja) adalah 14,73 kWh/m2/bln. Berdasarkan standar efisiensi Peraturan Menteri ESDM, hal ini termasuk pada kategori agak boros. Penghematan energi listrik dilakukan dengan menerapkan efisiensi sistem pencahayaan ruangan dan penggunaan AC dengan daya sesuai standar kebutuhan kesejukan ruangan serta penerapan pola hidup hemat energi listrik.
Hal yang dapat mempengaruhi umur transformator adalah pembebanan, temperature minyak trafo dan temperature sekitar. Pembebanan yang terlalu berat dapat menyebabkan perubahan temperature pada hot spot. Menurut IEC, transformator akan berumur normal yaitu 30 tahun pada temperature hot spot 98ºC dengan pembebanan yang terus menerus. Ketika temperature hot spot melewati batas yang telah ditetapkan maka hal ini dapat menyebabkan isolasi pada transformator akan mengalami penuaan yang cepat dari waktu normalnya. Isolasi menjadi cepat rusak dan temperature pada transformator akan naik yang akan menyebabkan nilai dari isolasi minyak menurun karena meningkatnya temperature minyak yang menyebabkan pergantian komposisi dan sifat dari minyak trafo. Penelitian ini dilakukan untuk mengetahui susut umur dari trafo daya 150 kV di GI Isimu. Metode penelitian yang digunakan pada penelitian ini adalah kuantitatif dengan metode analisis data. Data yang digunakan dalam penelitian ini adalah data real sistem pada PT. PLN (Pesreso) ULTG GI Isimu dan data temoerature dari BMKG Gorontalo. Berdasarkan perhitungan yang telah dilakukan, perhitungan beban konstan dengan pembebanan 100% diperoleh temperature hot spot sebesar 112,75ºC dan susut umur sebesar 5,49 pu/hari diperoleh perkiraan umur transformator yaitu 5,27 tahun, sedangkan perhitungan pembebanan pada tanggal 18 november 2019 diperoleh rata-rata temperature hot spot sebesar 73,42 ºC dan susut umur sebesar 0,0625 pu/hari diperoleh perkiraan umur transformator GI Isimu melebihi 30 tahun. Factors influencing the age of a transformer oil temperature, and ambient temperature. An overloaded transformer may cause changes in the hotspot temperature. According to the IEC, the transformer will last to its normal life of 30 years with a constant load at a hot spot temperature of 98 °C. When the hot spot temperature exceeds the predetermined limit, it will cause the insulation on the transformer resulting in rapid aging from its normal life. The insulation becomes swiftly damaged, affecting the increase of transformer temperature that will cause a decrease in the value of insulating oil. It is due to the increase in oil temperature, which causes changes in the composition and characteristics of the transformer oil. This research aims at determining the age loss of the 150 kV power transformer at GI Isimu. The research is quantitative, employing data analysis methods. The data are the real system data at PT. PLN (Persero) ULTG GI Isimu and the temperature data is from the Meteorological, Climatological, and Geophysical Agency (BMKG) of Gorontalo. Based on the calculations, the constant load calculation with 100% loading obtains a hot spot temperature of 112.75'C, and the age loss of 5,49 p.u/day obtains a life cxpectancy of 5.27 years. Furthermore, based on the calculation of loading on 18 November 201, the average hot spot temperature obtains 73.42°C, and the age loss of 0.0625 days obtains the life expectancy of the transformer at GI Isimu that excceds 30 years.
Data mentah yang belum di olah akan memperlambat proses penyampaian data, dengan menggunakan eksplorasi data analisis data yang akan di sampaikan akan lebih jelas dan dapat dipahami dengan mudah oleh pembaca. Data yang digunakan adalah data capaian Indikator Kinerja Utama (IKU) 3 Fakultas Teknik UNG Tahun 2021. IKU 3 terkait data dosen berkegiatan di luar kampus. Data IKU 3 FT UNG diperoleh dari capaian IKU 3 UNG yang telah diverifikasi Kementerian Pendidikan, Kebudayaan, Riset, dan Teknologi Tahun 2021. Data tersebut kemudian dilakukan Exploratory Data Analysis (EDA), sehingga didapatkan insight (wawasan) terhadap data tersebut. Proses yang terjadi adalah proses pengenalan masalah, pengumpulan data, pembersihan data dan kemudian analisis data eksplorasi. dari data yang didapatkan setelah melakukan EDA adalah untuk meningkatkan capaian IKU 3 Fakultas teknik UNG adalah dengan melakukan pengembangan terhadap dosen baru dan juga dosen yang belum pernah melakukan kegiatan di luar kampus. Dari data itu didapatkan pula data prodi yang paling banyak menyumbang dosen berkontribusi yaitu sebanyak 83%, dan juga prodi yang menyumbang paling rendah sekitar 18%. Dengan didapatkannya hasil ini, penentu kebijakan dapat mengambil keputusan untuk melakukan hal-hal yang dapat meningkatkan capaian IKU 3 Fakultas Teknik UNG. Raw data that has not been processed will slow down the process of conveying data, by using data exploration data analysis that will be conveyed will be clearer and can be easily understood by readers. The data used is the Main Performance Indicator (IKU) 3 achievement data for the Faculty of Engineering UNG in 2021. IKU 3 is related to lecturer data on activities outside the campus. The IKU 3 FT UNG data was obtained from the achievements of the IKU 3 UNG which have been verified by the Ministry of Education, Culture, Research and Technology in 2021. The data was then carried out by Exploratory Data Analysis (EDA), so that insight was obtained from the data. The process that occurs is the process of problem identification, data collection, data cleaning and then exploratory data analysis. from the data obtained after carrying out the EDA is to improve the achievement of IKU 3 UNG Faculty of engineering is to develop new lecturers and also lecturers who have never carried out activities outside the campus. From the data, it was also obtained that the study programs that contributed the most were lecturers, namely 83%, and also the study programs that contributed the lowest, around 18%. By obtaining these results, policy makers can make decisions to do things that can improve IKU 3 achievements at the UNG Faculty of Engineering.
Kapasitor bank memberikan manfaat dalam proses kinerja sistem distribusi dimana kapasitor bank dapat mengurangi losses, memperbesar kapasitas layanan dan mengurangi jatuh tegangan. Penempatan kapasitor bank diperlukan untuk menanggulangi permasalahan jatuh tegangan yang terjadi baik pada saluran transmisi bertegangan tinggi maupun saluran distribusi tegangan menengah. Penelitian mengenai Analisa Optimasi Penempatan Kapasitor Bank Pada Jaringan Tegangan Menengah 20 kV Feeder IS.03 Rayon Limboto Untuk Memperbaiki Kualitas Tegangan ini dilakukan dengan tujuan mendapatkan lokasi optimal dan rating kapasitor bank pada penyulang IS.03. Adapun metode yang digunakan dalam penelitian ini yaitu metode simulasi dimana metode simulasi merupakan bentuk penelitian yang bertujuan untuk mencari gambaran melalui sebuah sistem berskala kecil atau sederhana (model) dimana didalam model tersebut akan dilakukan manipulasi atau kontrol untuk melihat pengaruhnya. Berdasarkan hasil analisa dan pembahasan yang telah dilakukan pada penyulang IS.03 didapatkan kondisi paling optimum dengan jumlah kapasitor bank sebesar 6 x 150 kVAr dimana rata-rata selisih kenaikan tegangan ujung penyulang setelah pemasangan kapasitor bank sebesar 0.903 kV pada 3 (tiga) penyulang percabangan yaitu LI.03, LY.01, dan LY.02 yang mengalami jatuh tegangan melewati batas standar yang telah ditentukan.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.