We developed a continuous, volumetrically controlled veno-venous renal replacement system that can be operated in filtration or dialysis modes. We compared the clearances of substances with a range of molecular weights (MW) in each mode. Ten patients with acute renal failure underwent serial postdilutional hemofiltration and hemodialysis, for 30 min each, in sequence and in randomized order. All were receiving vancomycin for concurrent sepsis. The system incorporated a Filtral 10 AN69 artificial kidney; blood flow rate was 200 ml/min, and dialysate/filtrate flow rate was 25 ml/min. Sieving (SC) and diffusion (DC) co-efficients, for hemofiltration and hemodialysis, respectively, were identical for urea (MW 60; 1.01 +/- 0.05 vs 1.01 +/- 0.07) and creatinine (MW 113; 1.00 +/- 0.09 vs 1.01 +/- 0.06), and clearance equated with dialysate/filtrate flow. There was a modest difference in uric acid clearance (MW 168; SC 1.01 +/- 0.04 vs DC 0.97 +/- 0.04; p < 0.05). Vancomycin (MW 1,800) removal was 19% greater during filtration compared with dialysis (SC 0.87 +/- 0.10 vs DC 0.74 +/- 0.06; p < 0.01). For small solutes, the two modalities were equivalent. Vancomycin clearance was appreciably greater with hemofiltration, which is consistent with a greater potential for convection-based therapy in the removal of uremic and other middle molecules.
A preparation of low molecular weight heparin (Fragmin) was administered to patients with multiorgan failure receiving continuous venovenous hemodialysis. Three patients received a high-dose regimen (35 IU/kg bolus followed by 13 IU/kg infusion), and 7 received a low-dose regimen (8 and 5 IUlkg, respectively) for 36 h. High-dose Fragmin was associated with minimal clotting in the extracorporeal circuit. Plasma fibrinopeptide A levels declined, and mean anti-Xa activity was in the range 0.47-0.79 IUlml. The urea equilibration coefficient (UEC) (100% at initiation) remained above 90% throughout. All 3 patients had mild bleeding episodes, which led to discontinuation of Fragmin in I . During all low-dose treatments, marked thrombus formation occurred in the extracorpo-
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.