A centrifugal pump was installed in 1984 in the Fluid Mechanics Laboratory of Mechanical Engineering Department of Rajshahi University of Engineering & Technology. The motor of the centrifugal pump was dc motor and was not working. It could not be commissioned for a long time because of the damaged speed controller. The main shaft (rotor) was also jammed. In this project work, the dc motor was tried to repair. But it could not be run because the specification of the motor and the operating manual was not available. To complete the project successfully, the dc motor was replaced by an ac induction motor. After replacing the motor, the speed of the new motor was controlled by a variable frequency drive (VFD). Using this device, the speed was controlled from 600 rpm to 3000 rpm smoothly. After the replacement, the testing of the centrifugal pump was successfully performed and the motor was controlled in various speeds. Experiment on the performance test of the centrifugal pump was carried out satisfactorily running the pump in various speeds operated by the VFD.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.