Given the growing awareness of and concern for potential carcinogenic effects of exposure of children to ionizing radiation at CT, optimizing acquisition parameters is crucial to achieve diagnostically acceptable image quality at the lowest possible radiation dose. Among currently available dose reduction techniques, recent technical innovations have allowed the implementation of low tube voltage scans and iterative reconstruction (IR) techniques into daily clinical practice for pediatric CT. The benefits of lowering tube voltage include a considerable reduction in radiation dose and improved contrast on images, especially when an iodinated contrast medium is used. The increase in noise, which is attributed to decreased photon penetration, is a major drawback but is not as severe as that at adult CT because of the small body size of children. In addition, use of IR algorithms can suppress increased noise, yielding wider applicability for low tube voltage scans. However, a careful implementation strategy and methodologic approach are necessary to maximize the potential for dose reduction while preserving diagnostic image quality under each clinical condition. The potential pitfalls of and topics related to these techniques include (a) the effect of tube voltage on the surface radiation dose, (b) the effect of window settings, (c) accentuation of metallic artifacts, (d) deterioration of low contrast detectability at low-dose settings, (e) interscanner variation of x-ray spectra, and (f) a comparison with the use of a spectral shaping technique. Appropriate use of low tube voltage and IR techniques is helpful for radiation dose reduction in most applications of pediatric CT. Online DICOM image stacks are available for this article . RSNA, 2018.
These results indicated that radical surgery should be performed for patients with no distant metastasis, and that chemotherapy might be a useful alternative treatment for patients with distant metastasis in advanced carcinoma of the gallbladder.
Patients with syndrome X with abnormal exercise scintigrams have high susceptibility to myocardial ischemia during exercise or pharmacologic stress tests, probably owing to reduced coronary flow reserve. A heterogeneous response to endogenous adenosine may contribute to scintigraphic perfusion abnormalities and myocardial ischemia during exercise in this subset of patients with syndrome X.
The 80-kVp acquisition with SAFIRE yields better image quality for BSCTA and substantial reduction in the radiation and CM dose compared to the 120-kVp with FBP protocol.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.