Radiation-grafted membranes can be considered an alternative to perfluorosulfonic acid (PFSA) membranes, such as Nafion, in a solid polymer electrolyte electrolyzer. Styrene, acrylonitrile, and 1,3-diisopropenylbenzene monomers are cografted into preirradiated 50 μm ethylene tetrafluoroethylene (ETFE) base film, followed by sulfonation to introduce proton exchange sites to the obtained grafted films. The incorporation of grafts throughout the thickness is demonstrated by scanning electron microscopy/energy-dispersive X-ray spectroscopy (SEM/EDX) analysis of the membrane cross-sections. The membranes are analyzed in terms of grafting kinetics, ion-exchange capacity (IEC), and water uptake. The key properties of radiation-grafted membranes and Nafion, such as gas crossover, area resistance, and mechanical properties, are evaluated and compared. The plot of hydrogen crossover versus area resistance of the membranes results in a property map that indicates the target areas for membrane development for electrolyzer applications. Tensile tests are performed to assess the mechanical properties of the membranes. Finally, these three properties are combined to establish a figure of merit, which indicates that radiation-grafted membranes obtained in the present study are promising candidates with properties superior to those of Nafion membranes. A water electrolysis cell test is performed as proof of principle, including a comparison to a commercial membrane electrode assembly (MEA).
The period following heart failure hospitalization (HFH) is a vulnerable time with high rates of death or recurrent HFH.OBJECTIVE To evaluate clinical characteristics, outcomes, and treatment response to vericiguat according to prespecified index event subgroups and time from index HFH in the Vericiguat Global Study in Subjects With Heart Failure With Reduced Ejection Fraction (VICTORIA) trial. DESIGN, SETTING, AND PARTICIPANTSAnalysis of an international, randomized, placebo-controlled trial. All VICTORIA patients had recent (<6 months) worsening HF (ejection fraction <45%). Index event subgroups were less than 3 months after HFH (n = 3378), 3 to 6 months after HFH (n = 871), and those requiring outpatient intravenous diuretic therapy only for worsening HF (without HFH) in the previous 3 months (n = 801). Data were analyzed between May 2, 2020, and May 9, 2020.INTERVENTION Vericiguat titrated to 10 mg daily vs placebo. MAIN OUTCOMES AND MEASURESThe primary outcome was time to a composite of HFH or cardiovascular death; secondary outcomes were time to HFH, cardiovascular death, a composite of all-cause mortality or HFH, all-cause death, and total HFH. RESULTS Among 5050 patients in the VICTORIA trial, mean age was 67 years, 24% were women, 64% were White, 22% were Asian, and 5% were Black. Baseline characteristics were balanced between treatment arms within each subgroup. Over a median follow-up of 10.8 months, the primary event rates were 40.9, 29.6, and 23.4 events per 100 patient-years in the HFH at less than 3 months, HFH 3 to 6 months, and outpatient worsening subgroups, respectively. Compared with the outpatient worsening subgroup, the multivariable-adjusted relative risk of the primary outcome was higher in HFH less than 3 months (adjusted hazard ratio, 1.48; 95% CI, 1.27-1.73), with a time-dependent gradient of risk demonstrating that patients closest to their index HFH had the highest risk. Vericiguat was associated with reduced risk of the primary outcome overall and in all subgroups, without evidence of treatment heterogeneity. Similar results were evident for all-cause death and HFH. Addtionally, a continuous association between time from HFH and vericiguat treatment showed a trend toward greater benefit with longer duration since HFH. Safety events (symptomatic hypotension and syncope) were infrequent in all subgroups, with no difference between treatment arms.CONCLUSIONS AND RELEVANCE Among patients with worsening chronic HF, those in closest proximity to their index HFH had the highest risk of cardiovascular death or HFH, irrespective of age or clinical risk factors. The benefit of vericiguat did not differ significantly across the spectrum of risk in worsening HF.
Radiation-grafted membranes are a promising alternative to commercial membranes for water electrolyzers, since they exhibit lower hydrogen crossover and area resistance, better mechanical properties, and are of potentially lower cost than perfluoroalkylsulfonic acid membranes, such as Nafion. Stability is an important factor in view of the expected lifetime of 40 000 h or more of an electrolyzer. In this study, combinations of styrene (St), α-methylstyrene (AMS), acrylonitrile (AN), and 1,3-diisopropenylbenzene (DiPB) are cografted into 50 μm preirradiated poly(ethylene-co-tetrafluoroethylene) (ETFE) base film, followed by sulfonation to produce radiation-grafted membranes. The stability of the membranes with different monomer combinations is compared under an accelerated stress test (AST), and the degradation mechanisms are investigated. To mimic the conditions in an electrolyzer, in which the membrane is always in contact with liquid water at elevated temperature, the membranes are immersed in water for 5 days at 90 °C, so-called thermal stress test (TST). In addition to testing in air atmosphere tests are also carried out under argon to investigate the effect of the absence of oxygen. The water is analyzed with UV-vis spectroscopy and ion chromatography. The ion exchange capacity (IEC), swelling degree, and Fourier transform infrared (FTIR) spectra of the membranes are compared before and after the test. Furthermore, energy-dispersive X-ray (EDX) spectroscopic analysis of the membrane cross-section is performed. Finally, the influence of the TST to the membrane area resistance and hydrogen crossover is measured. The stability increases along the sequence St/AN, St/AN/DiPB, AMS/AN, and AMS/AN/DiPB grafted membrane. The degradation at the weak-link, oxygen-induced degradation, and hydrothermal degradation are proposed in addition to the "swelling-induced detachment" reported in the literature. By mitigating the possible paths of degradation, the AMS/AN/DiPB grafted membrane is shown to be the most stable membrane and, therefore, it is a promising candidate for a membrane to be used in a water electrolyzer.
A catalog is a register of all bibliographic items found in a library. A bibliographic item can be any information entity. The library catalog has evolved from manual, website based catalog to mobile catalog. Unfortunately, there are still many obstacles in the results of library catalog search, including the relevant results of documents based on input from the user. The purpose of this research is to make the library catalog based on mobile application in android using relevant calculation used rocchio relevance feedback method. Terms— android, library, library catalog, mobile, rocchio.
The aquaculture industry is developing tremendously over the past two decades following the significant decline of the world’s fish catch. Nevertheless, small scale fish farmers are still one of the most vulnerable communities in Indonesia. In their attempt to carry out successful aquaculture business, small scale fish farmers encounter several challenges that inhibit the fish farmers in ensuring the sustainability of fish products. This research aims to explore challenges and identify internal and external challenges that affect fish farmers’ activities in ensuring fish product sustainability. This research used a quantitative approach by collecting data through questionnaire distribution to small scale fish farmers in Central Java and data was analyzed using statistical analysis package. The findings of this research showed that challenges are classified into nine internal and seven external challenges. Result of statistical analysis indicated that internal challenges influenced product sustainability through water quality examination, whereas external challenges influenced product sustainability through two activities, i.e. giving feed at the right quantity and time, and maintain fish seed quality and availability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.