Two stormwater control measures (SCMs) installed in series were monitored for their individual impact on the hydrology and water quality of stormwater runoff from a 0.08-hectare watershed in Fayetteville, North Carolina, for 22 months. Runoff was first treated by permeable interlocking concrete pavement (PICP), the underdrain of which discharged into a proprietary box filter (Filterra ® biofiltration) which combined high-flow-engineered media with modest biological treatment from a planted tree. Due to a deteriorating contributing drainage area and high ratio of impervious area to permeable pavement area (2.6:1), clogging of the permeable pavement surface caused an estimated 38% of stormwater to bypass as surface runoff. Fifty-six percent of runoff volume infiltrated underlying soils, and the remaining 6% exited the Filterra ® as treated effluent; the hydrologic benefit of the Filterra ® was minimal, as expected. Primary treatment through the PICP significantly reduced event mean concentrations (EMCs) of total suspended solids (TSS), total phosphorus (TP), total nitrogen (TN), and total Kjeldahl nitrogen (TKN) but contributed to a significant increase in nitrate/nitrite (NO 2,3-N) concentrations. Secondary treatment by the Filterra ® further reduced TSS and TP concentrations and supplemented nitrogen removal such that treatment provided by the overall system was as follows: TSS (removal efficiency (RE): 96%), TP (RE: 75%), TN (RE: 42%), and TKN (RE: 51%). EMCs remained unchanged for NO 2,3-N. Despite EMC reductions, additional load reduction due to the Filterra ® was modest (less than 2%). This was because (1) a majority of pollutant load was removed via PICP exfiltration losses, and (2) nearly all of the export load was from untreated surface runoff, which bypassed the Filterra ® , and therefore the manufactured device never had the opportunity to treat it. Cumulative load reductions (based only upon events with samples collected at each sampling location) were 69%, 60%, and 41% for TSS, TP, and TN, respectively. When surface runoff was excluded, load reductions increased to over 96%; lower run-on ratios (which would reduce clogging rate) and/or increased maintenance frequency might have improved pollutant load removal.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.