BACKGROUND AND OBJECTIVE:
To provide new insights into toxic maculopathy secondary to pentosan polysulfate (PPS) utilizing multimodal testing.
PATIENTS AND METHODS:
Retrospective case-series of four patients from two academic centers evaluated with multimodal imaging, electrophysiology, dark adaptometry (DA), and genetic testing.
RESULTS:
Median age was 58 years, exposure to PPS was 18.5 years, and cumulative dose of was 2,025 grams. Seven of eight eyes had visual acuity of 20/40 or better. Optical coherence tomography (OCT) angiography demonstrated increased choriocapillaris flow voids (54.25%) in cases compared to controls (13.2%). Two subjects had abnormal foveal avascular zone configurations. Two subjects demonstrated collapse of the retinal pigment epithelium nodular excrescences and progressive retinal thinning over 4 to 5 years on OCT. Electrophysiology was normal (3/3 patients), but DA was delayed (2/2 patients).
CONCLUSIONS:
The authors describe novel findings of PPS maculopathy, including flow voids in the choriocapillaris. Progressive retinal thinning may suggest a secondary retinal effect. These findings may improve understanding of the pathophysiology.
[
Ophthalmic Surg Lasers Imaging Retina
. 2021;52:13–22.]
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.