Results of field measurements of the gamma radiation dose with a frequency domain optical reflectometer are presented. The ability to measure doses up to 100 kGy remotely with an accuracy of up to 20% and reconstruct the absorbed dose distribution profile with a resolution of 15 cm for doses up to 9 kGy is demonstrated. The factors affecting the dynamic range and accuracy of measurements are discussed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.