Bored piles settlement behavior under vertical loaded is the main factor that affects the design requirements of single or group of piles in soft soils. The estimation of bored pile settlement is a complicated problem because it depends upon many factors which may include ground conditions, validation of bored pile design method through testing and validation of theoretical or numerical prediction of the settlement value. In this study, a prototype single and bored pile group model of arrangement (1*1, 1*2 and 2*2) for total length to diameter ratios (L/D) is 13.33 and clear spacing three times of diameter, subjected to vertical axial loads. The bored piles model used for the test was 2000 mm in length, and 150 mm in diameter has been constructed in soft clayey soils. Furthermore, different theoretical methods have been used for the estimation of bored pile settlement, such as Poulos and Vesic's methods and then their comparison with the pile load test data based on the quick pile load test as presented in (ASTM-D1143, 2007). In general, the theoretical method for estimation the bored pile settlement by Poulos and Vesic's gives higher value of the settlement for the single and group bored pile compared to the pile settlement results obtained from field pile load test data. Therefore, it is not recommended to be used for soft clayey soils. On the other hand, Hansen’s 90% and Butler and Hoy’s results may be considered reliable interpretation method to compute the settlement of single and group bored pile.
The improvement of the mechanical soil characteristics of jet grouting technique is very attractive. The jet grouted soil cement columns in soft is a complicated issue because it depends on a number of factors such as, soil nature, mixture, influence among soil and grouting materials, jetting force of nozzle, jet grouting and water flow rate, rotation and lifting speed. This paper discusses the estimation of shear strength parameters of soil-cement column (soilcrete) in soft clayey soil based on the relationships between the unconfined compressive and split tensile strength for the soilcrete and the effect of the jet grouting and water pressure in the values of cohesion and internal friction. For this reason, theoretical and field work models have been developed. The relation between split tensile and unconfined compressive strength results were used to draw a Mohr’s circle and failure enveloped to define the shear strength parameters of soilcrete. According to that, the results indicate that the resistance of the jet grout columns increases by increasing the nominal resistance of the grouting material (cement), water and jet grouting pressure. The shear resistance variables are increased by increasing the unconfined compressive and tensile strength of the jetting column. The value of the unconfined compressive strength ranges from (2.78-5.52 MPa). While the internal friction angle varies from 38° to 44°. On the other hand, the tensile strength is increased by increasing the unconfined compressive strength and ranges from (0.66-1.02 MPa).
The evaluation of axial capacity of jet grouted soil cement columns in soft soil is a complicated issue because it depends according to the number of factors such as, soil type, influence mixture between soil and grouting materials, nozzle jet energy, jet grouting and water flow rate, rotation and lifting speed. These parameters related to the type of jet grouting methods (single, double and triple system). Most methods of design the bearing capacity of the jet-grouting column based on experience. Therefore, some designer calculates the bearing capacity of the jet grouting column based on jet grout section capacity. In this paper, different theoretical methods have been used to estimate of the jet grouting soil-cement capacity, such as Poulos and Davis, 1980 methods and then their comparison with the pile load test calculations based on the quick pile load test as presented in ASTM-D1143-07. Therefore, the study describes a prototype test single and group jet grout soil-cement models of arrangement (1*1, 1*2 and 2*2) for total length to diameter ratios (L/D) is 13.33 and clear spacing three times of diameter has been constructed in soft clayey soils in the right bank of the Euphrates River, at Al- Nasiriyah city. As a result, the theoretical method for estimation the bearing capacity gives unfaithful values for the single and group jet grout column compared to the load- settlement calculations obtained from field pile load test data. On the other hand, the Hansen’s 90% and Butler and Hoy’s given closer results to each other and may be considered faithful interpretation methods to compute the bearing capacity of single and group jet grouting columns.
The settlement evaluation for the jet grouted columns (JGC) in soft soils is a problematic matter, because it is influenced by the number of aspects such as soil type, effect mixture between soil and grouting materials, nozzle energy, jet grouting, water flow rate, rotation and lifting speed. Most methods of design the jet-grouting column based on experience. In this study, a prototype single and group jet grouting models (single, 1*2, and 2*2) with the total length and diameter were (2000 and 150 mm) respectively and clear spacing (3D) has been constructed in soft clay and subjected to vertical axial loads. Furthermore, different theoretical methods have been used for the estimation of (JGC) settlement. Pile load settlement analysis of the jet grout columns showed that the average settlement values were (0.41, 0.663, and 1.5 mm) for the single, group (1*2) and group (2*2) jet grouted columns respectively. While, in the theoretical methods give a higher value of the settlement (2.0, 3.48, and 5.24 mm) for the single, group (1*2) and group (2*2) jet grouted columns compared with the settlement results acquired from field pile load test data. Therefore, it is not recommended to be used for soft clay. On the other hand, Fuller and Hoy’s, Hansen’s 90%, and Butler and Hoy’s results may be considered faithful interpretation methods for the single and group (1*2 and 2*2) (JGC).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.