We detected Zika virus in breast milk of a woman in Brazil infected with the virus during the 36th week of pregnancy. Virus was detected 33 days after onset of signs and symptoms and 9 days after delivery. No abnormalities were found during fetal assessment or after birth of the infant.
Objective: To evaluate the efficacy and safety of nasal continuous positive airway pressure (NCPAP) using devices with variable flow or bubble continuous positive airway pressure (CPAP) regarding CPAP failure, presence of air leaks, total CPAP and oxygen time, and length of intensive care unit and hospital stay in neonates with moderate respiratory distress (RD) and birth weight (BW) ≥ 1,500 g. Methods:Forty newborns requiring NCPAP were randomized into two study groups: variable flow group (VF) and continuous flow group (CF). The study was conducted between October 2008 and April 2010. Demographic data, CPAP failure, presence of air leaks, and total CPAP and oxygen time were recorded. Categorical outcomes were tested using the chi-square test or the Fisher's exact test. Continuous variables were analyzed using the Mann-Whitney test. The level of significance was set at p < 0.05. Results:There were no differences between the groups with regard to demographic data, CPAP failure (21.1 and 20.0% for VF and CF, respectively; p = 1.000), air leak syndrome (10.5 and 5.0%, respectively; p = 0.605), total CPAP time (median: 22.0 h, interquartile range [IQR]: 8.00-31.00 h and median: 22.0 h, IQR: 6.00-32.00 h, respectively; p = 0.822), and total oxygen time (median: 24.00 h, IQR: 7.00-85.00 h and median: 21.00 h, IQR: 9.50-66.75 h, respectively; p = 0.779). Conclusion:In newborns with BW ≥ 1,500 g and moderate RD, the use of continuous flow NCPAP showed the same benefits as the use of variable flow NCPAP.J Pediatr (Rio J). 2011;87(6):499-504: Infant, newborn, ventilation, neonatal intensive care units. ResumoObjetivo: Avaliar a eficácia e segurança da pressão positiva contínua na via aérea (CPAP) utilizando aparelhos de fluxo variável e fluxo contínuo em selo d'água, quanto a falha do CPAP, ocorrência de escape de ar, tempo de uso de CPAP e de oxigênio e tempo de internação em unidade de terapia intensiva e hospitalar em neonatos com desconforto respiratório (DR) moderado e peso de nascimento (PN) ≥ 1.500 g. Métodos:Quarenta recém-nascidos que necessitavam de CPAP foram randomizados em dois grupos: um grupo tratado com fluxo variável (FV) e outro com fluxo contínuo (FC). O estudo foi realizado entre outubro de 2008 e abril de 2010. Foram registrados dados demográficos, falha do CPAP, ocorrência de escape de ar, tempo de uso de CPAP e de oxigênio, entre outros. Os desfechos categóricos foram analisados com o teste do qui-quadrado ou exato de Fisher e as variáveis contínuas com o teste de Mann-Whitney, com significância de p < 0,05. Resultados:Não houve diferença quanto aos dados demográficos, falha do CPAP (21,1 e 20,0% para o FV e o FC, respectivamente; p = 1,000), síndrome de escape de ar (10,5 e 5,0%, respectivamente; p = 0,605), tempo de CPAP [mediana: 22,0 h, intervalo interquartil (IIQ): 8,00-31,00 h e mediana: 22,0 h, IIQ: 6,00-32,00 h, respectivamente; p = 0,822), e tempo de uso de oxigênio (mediana: 24,00 h, IIQ:7,00-85,00 h e mediana: 21,00 h, IIQ:9,50-66,75 h, respectivamente; p = 0,779). Conclusão:Em r...
Objective:To investigate the influence of the site of measurement of transcutaneous bilirubin (forehead or sternum) in reproducibility of results as compared to plasma bilirubin.Methods:A cohort study including 58 term newborns with no hemolytic disease. Transcutaneous measurements were performed on the forehead (halfway between the headline and the glabella, from the left toward the right side, making consecutive determinations, one-centimeter apart) and the sternum (five measurements, from the suprasternal notch to the xiphoid process with consecutive determinations, one-centimeter apart) using Bilicheck® (SpectRx Inc, Norcross, Georgia, USA). The correlation and agreement between both methods and plasma bilirubin were calculated.Results:There was a strong linear correlation between both determinations of serum bilirubin at the forehead and sternum (r=0.704; p<0.01 and r=0.653; p<0.01, respectively). There was correspondence of the mean values of transcutaneous bilirubin measured on the sternum (9.9±2.2mg/dL) compared to plasma levels (10.2±1.7mg/dL), but both differ from the values measured on the forehead (8.6±2.0mg/dL), p<0.05.Conclusion:In newborn term infants with no hemolytic disease, measuring of transcutaneous bilirubin on the sternum had higher accuracy as compared to serum bilirubin measurement on the forehead.
Objective:To identify clinical and echocardiographic parameters associated with the evolution of the ductus arteriosus in neonates with birth weight lower than 1,500g.Methods:Retrospective study of 119 neonates in which clinical parameters (Prenatal: maternal age, risk of infection and chorioamnionitis, use of corticosteroid, mode of delivery and gestational age. Perinatal: weight, Apgar score, gender and birth weight/gestational age classification; Postnatal: use of surfactant, sepsis, fluid intake, heart murmur, heart rate, precordial movement and pulses, use of diuretics, oxygenation index, desaturation/apnea, ventilatory support, food intolerance, chest radiography, renal function, hemodynamic instability, and metabolic changes) and echocardiographic parameters (ductus arteriosus diameter, ductus arteriosus/weight ratio, left atrium/ aorta ratio, left ventricular diastolic diameter, and transductal flow direction, pattern and velocity) were analyzed. The clinical and echocardiographic parameters analyzed were considered statistically significant when p<0.05.Results:In the 119 neonates, the incidence of patent ductus arteriosus was 61.3%; 56 received treatment (46 pharmacological and 10 surgical treatment), 11 had spontaneous closure, 4 died, and 2 were discharged with patent ductus arteriosus. A higher incidence of chorioamnionitis, use of surfactant, lower weight and gestational age, sepsis, heart murmur, ventilatory support and worse oxygenation indices were observed in the neonates receiving treatment. The group with spontaneous closure had a smaller ductus arteriosus diameter, lower ductus arteriosus/weight ratio, and higher transductal flow velocity.Conclusion:Based on clinical and echocardiographic parameters, the neonates with spontaneous closure of the ductus arteriosus could be differentiated from those who required treatment.
OBJECTIVES:Nasal continuous positive airway pressure is used as a standard of care after extubation in very-low-birth-weight infants. A pressure of 5 cmH2O is usually applied regardless of individual differences in lung compliance. Current methods for evaluation of lung compliance and air distribution in the lungs are thus imprecise for preterm infants. This study used electrical impedance tomography to determine the feasibility of evaluating the positive end-expiratory pressure level associated with a more homogeneous air distribution within the lungs before extubation.METHODS:Ventilation homogeneity was defined by electrical impedance tomography as the ratio of ventilation between dependent and non-dependent lung areas. The best ventilation homogeneity was achieved when this ratio was equal to 1. Just before extubation, decremental expiratory pressure levels were applied (8, 7, 6 and 5 cmH20; 3 minutes each step), and the pressure that determined the best ventilation homogeneity was defined as the best positive end-expiratory pressure.RESULTS:The best positive end-expiratory pressure value was 6.3±1.1 cmH20, and the mean continuous positive airway pressure applied after extubation was 5.2±0.4 cmH20 (p = 0.002). The extubation failure rate was 21.4%. X-Ray and blood gases after extubation were also checked.CONCLUSION:This study demonstrates that electrical impedance tomography can be safely and successfully used in patients ready for extubation to suggest the best ventilation homogeneity, which is influenced by the level of expiratory pressure applied. In this feasibility study, the best lung compliance was found with pressure levels higher than the continuous positive airway pressure levels that are usually applied for routine extubation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.