Background Highly accurate detection of intracranial hemorrhages (ICH) on head computed tomography (HCT) scans can prove challenging at high-volume centers. This study aimed to determine the number of additional ICHs detected by an artificial intelligence (AI) algorithm and to evaluate reasons for erroneous results at a level I trauma center with teleradiology services. Methods In a retrospective multi-center cohort study, consecutive emergency non-contrast HCT scans were analyzed by a commercially available ICH detection software (AIDOC, Tel Aviv, Israel). Discrepancies between AI analysis and initial radiology report (RR) were reviewed by a blinded neuroradiologist to determine the number of additional ICHs detected and evaluate reasons leading to errors. Results 4946 HCT (05/2020-09/2020) from 18 hospitals were included in the analysis. 205 reports (4.1%) were classified as hemorrhages by both radiology report and AI. Out of a total of 162 (3.3%) discrepant reports, 62 were confirmed as hemorrhages by the reference neuroradiologist. 33 ICHs were identified exclusively via RRs. The AI algorithm detected an additional 29 instances of ICH, missed 12.4% of ICH and overcalled 1.9%; RRs missed 10.9% of ICHs and overcalled 0.2%. Many of the ICHs missed by the AI algorithm were located in the subarachnoid space (42.4%) and under the calvaria (48.5%). 85% of ICHs missed by RRs occurred outside of regular working-hours. Calcifications (39.3%), beam-hardening artifacts (18%), tumors (15.7%), and blood vessels (7.9%) were the most common reasons for AI overcalls. ICH size, image quality, and primary examiner experience were not found to be significantly associated with likelihood of incorrect AI results. Conclusion Complementing human expertise with AI resulted in a 12.2% increase in ICH detection. The AI algorithm overcalled 1.9% HCT. Trial registration German Clinical Trials Register (DRKS-ID: DRKS00023593).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.