Optical microcavities provide a possible method for boosting the detection sensitivity of biomolecules. Silica-based microcavities are important because they are readily functionalized, which enables unlabeled detection. While silica resonators have been characterized in air, nearly all molecular detections are performed in solution. Therefore, it is important to determine their performance limits in an aqueous environment. In this letter, planar microtoroid resonators are used to measure the relationship between quality factor and toroid diameter at wavelengths ranging from visible to near-IR in both H 2 O and D 2 O, and results are then compared to predictions of a numerical model. Quality factors ͑Q͒ in excess of 10 8 , a factor of 100 higher than previous measurements in an aqueous environment, are observed in both High-Q and ultra-high-Q ͑UHQ͒ silica optical microcavities can perform as highly sensitive detectors; 1-3 they derive their excellent transduction abilities from long photon lifetimes within the whispering gallery of the microcavity. Unlike their optical waveguide counterparts, wherein the photon interacts with a functionalized surface only once, 4,5 recirculation within the microcavity allows photons to interact with the surface many times. Additionally, the surface of silica-based microcavities is easily sensitized using silanization agents, 6 amines, carbohydrates, the biotin-streptavidin system, 7 or antibodies. 8 For example, silica microsphere resonators, with a properly sensitized surface, were recently used to distinguish between two strands of DNA. 9 However, while detailed studies have been performed to determine the limits of a resonator's quality factor in air, 10-12 no comparable studies have been performed in water. Because most detection experiments are performed in a water-based solution, it is important to thoroughly understand the impact of this environment on the relationship between the diameter of the microtoroid resonator and the operational wavelengths of interest.To this end, UHQ silica microtoroid resonators were fabricated over a wide range ͑50-250 m͒ of major toroid diameters as shown in Fig. 1. 13 Experiments were performed in both water ͑H 2 O͒ and deuterium oxide ͑D 2 O͒. The D 2 O was purchased from Aldrich. D 2 O was chosen as the second liquid because it has the same refractive index and, in turn, the same radiation loss as H 2 O. However, its absorption at all wavelengths tested is significantly less. 14 This allowed for selective probing of the absorption-loss mechanism and verification of the model developed to describe this system.The model used finite element analysis to predict the Q-factor of microtoroid resonators immersed in water or D 2 S and accounted for two loss mechanisms: radiation loss and absorption loss. The absorption loss was numerically calculated at ͑680, 1300, 1570͒ nm using published values of H 2 O ͑0.0045, 1.12, 8.79͒ cm −1 and D 2 O ͑2.46 ϫ 10 −4 , 0.105, 0.327͒ cm −1 . 14 The modeling of radiation loss uses a fully vectorial two-dimensio...
Abstract-Using ultra-high-Q toroid microcavity masters, soft lithography is applied to fabricate polymer microcavity arrays with Q factors in excess of 10 6 . This technique produces resonators with material-limited quality factors.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.