Introduction. Research and clinical settings use the 10-meter walk test (10MWT) to measure locomotor capacity with considerable methodological diversity. Comparison between healthy and disabled children is frequent; however, the reproducibility of 10MWT using different methods is unknown. Objectives. This study analysed intrasubject, test-retest reliability, and agreement of four methods of 10MWT, exploring the influence of pace, acceleration-deceleration phases, and anthropometric measurements when calculating mean velocity. Methods. This cross-sectional study evaluated 120 typical children, both sexes, aged 6, 8, 10, and 12 (n=30 for each age). The mean times and velocities of the path (10 m) and middle path (6 m) obtained at a self-selected and fast pace were analysed. Initial assessment and another after seven days recorded three measurements per method (sV6 = self-selected pace and 6 m; sV10 = self-selected pace and 10 m; fV6 = fast pace and 6 m; fV10 = fast pace and 10 m). Interclass correlation coefficient (ICC), multiple regression, and Snedecor-F test (5% significance level) were used. Results. The fV10 method had high intrasubject reliability for all tested ages (0.70<ICC>0.89); sV10 exhibited high intrasubject reliability for ages 6, 8, and 12 (0.70<ICC>0.89) and moderate for age 10 (0.50<ICC<0.69).Test-retest reliability at sV6 and fV6 did not reach high ICC in any tested ages. The test-retest reliability at sV10 and fV10 was moderate for ages 6, 8, and 12 (0.50<ICC>0.69) and poor for age 10 (0.25<ICC>0.49). There was no agreement between methods: sV6 versus sV10 (mean difference=0.91 m/s; SEM=0.036); fV6 versus fV10 (mean difference=1.70; SEM=0.046). The fV6 method versus fV10 overestimated the velocity (bias=1.70 m/s). Conclusions. For typical children, the method that ensured the highest intrasubject reliability used fast pace and 10 m. Moreover, test-retest reliability increased when adopting 10 m at both self-selected and fast pace. The methods were not equivalent but were related, and those that did not compute the entire pathway overestimated the results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.