Study Design: A literature review.Objective: To summarize the implant removal rate, common bacterial organisms found, time of onset, ratio of superficial to deep infection, and regurgitating the prevalence among all the retrospective and prospective studies on management and characterization of surgical site infections (SSIs).
Methods:PubMed was searched for articles published between 2000 and 2018 on the management or characterization of SSIs after spinal surgery. Only prospective and retrospective studies were included. Results: A total of 49 articles were found relevant to the objective. These studies highlighted the importance of implant removal to avoid recurrence of SSI. The common organisms detected were methicillin-resistant Staphylococcus aureus, methicillin-resistant Staphylococcus epidermis, Staphylococcus epidermis, Staphylococcus aureus, and Propionibacterium acnes, with prevalence of 1% to 15%. A major proportion of all were deep SSI, with minority reporting on late-onset SSI. Conclusion: Long-term antibiotics administration, and continuous irrigation and debridement were common suggestion among the authors; however, the key measure undertaken or implied by most authors to avoid risk of recurrence was removal or replacement of implants for late-onset SSI.
Introduction: Recent literature identifies similar failure rates such as anchor pull-out and rod breakage, but a higher unplanned revision surgery with MAGEC rods than with traditional growth rods. Besides known failure modes such as rod fracture, infection, etc., failure to noninvasively distract the rods was cited as the main cause of such unplanned surgeries. The source of these data ranges from multicenter cohort studies to singular case series. These studies included explanted implants that had undergone failure in distraction mechanism, rod fracture, or infection, or had reached their maximum length. Nevertheless, in addition to identifying the overall mode of failure, it is equally important to identify the large-scale incidence of exclusive failures in comparison with standard instrumentation failure modes in spine surgery. Method: The US Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) databases were searched for reports on MAGEC rods, and on standard instrumentation used for spinal fusion. The adverse events were recorded, tabulated, and analyzed. 2 Results: A search of the US FDA MAUDE database yielded reports of 163 device-related adverse events. These included distraction mechanism failure (n=129), rod fracture (n=24), and minor voluntary reports of infection and tissue discoloration (n=10). For standard instrumentation usage in spine surgery, pedicle screw breakage post surgery (n=336), set screw damage during surgery (n=257), rod breakage post surgery (n=175), interbody cage breakage during surgery (n=118), and pedicle screw breakage during surgery (n=75) were identified as the top 5 failure modes. Conclusion: The study identified the distraction mechanism failure as the most common and growing complication associated with MAGEC rod usage in children with scoliosis, leading to unplanned invasive revision surgeries.
We hypothesized that the new posterior bilateral system would significantly decrease motion compared to the intact spine. This cadaver study showed that the proposed new posterior fusion technique IOTF fused the index segment in a similar fashion to the classical pedicle screw fusion technique.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.