Indoor radon level measurements were carried out in 42 dwellings in Bethlehem, Palestine, using CR-39 solid state nuclear track detectors. The measurements were performed during winter and spring seasons of the year 2010, for a period ranging from 97-118 d using a total of 100 detectors. The detectors were installed in living rooms, bedrooms, kitchens, and storage areas of 39 houses, as well as in three schools, selected randomly in the surveyed area. The results of indoor radon levels and the annual effective dose in houses were found to vary from 26 - 611 Bq m(-3) and 0.65 - 14.1 m Sv y(-1), with average values of 117.0 Bq m(-3) and 2.95 m Sv y(-1), respectively. The mean values of radon concentration levels in bedrooms, kitchens, living rooms, basements, and storage areas are, respectively, 106.5, 113.1, 101.5, and 164.2 Bq m(-3). The corresponding mean values of annual effective dose for the bedrooms, kitchens, living rooms, basements, and storage areas are 2.66, 2.83, 2.54, 14.1 m Sv y(-1), respectively. In schools, the radon levels are found to vary from 31 - 400 Bq m(-3) with an average value of 125.1 Bq m(-3). The average annual effective dose in schools is found to be 3.12 mSv y(-1). This value is higher than the assigned international value. In general, the results show that radon concentration levels in 83% of the investigated dwellings are lower than the indoor radon action level of 150 Bq m(-3) for the United States.
This study presents the seasonal variations of indoor radon levels in dwellings located in the Ramallah province and East Jerusalem suburbs, Palestine. The measurements were performed during the summer and winter of the year 2006/2007 using CR-39 solid-state-nuclear-track detectors. The total number of investigated buildings is 75 in summer and 81 in winter. A total number of 142 dosemeters are installed in dwellings for each season for a period of almost 100 d. The radon concentration levels in summer varied from 43 to 192 Bq m(-3) for buildings in the Ramallah province and from 30 to 655 Bq m(-3) for East Jerusalem suburbs. In winter, the radon concentration levels are found to vary from 38 to 375 Bq m(-3) in the Ramallah buildings and from 35 to 984 Bq m(-3) in East Jerusalem suburbs. The obtained results for radon concentration levels in most places are found to be within the accepted international levels.
In this study, we report on the indoor radon concentration levels in a number of locations scattered in the Hebron province, Palestine. The measurements were performed during the winter season of the year 1999/2000 using the CR-39 detectors. The radon concentration levels were found to vary from 23 to 580 Bq m(-3). The arithmetic average of the obtained radon concentration levels was found to be 91 Bq m(-3). It was found that most of the radon concentration levels in houses and school rooms are below the low reference levels limits. Most of the high-radon concentration levels were found in unpainted storage rooms.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.