Lung cancer is the most prevalent malignancy in western countries and most of the patients present at advanced stages, but single splenic metastasis is exceptional instead. We report on a case of a seventy- three-year old male presenting with non-hemoptoic productive cough, constitutional syndrome and pain in the left lower quadrant. Physical examination and complementary radiological and histological procedures revealed the presence of an adenocarcinoma of the left lung with probable splenic metastasis. The patient underwent splenectomy, which confirmed the diagnose of splenic metastasis of lung adenocarcinoma and, secondly, lung resection was performed. Topics about lung cancer metastasis are discussed.
Introduction: performing anal endosonography in complex fistula-in-ano allows us to design a personalized surgical strategy in each case, thereby improving results. However, there are doubts in the literature as to its utility in recurrent complex fistulas. The aim of this study was to compare the utility of anal ultrasonography in the study of primary versus recurrent complex fistula-inano.Patients and method: prospective study of patients diagnosed and treated for complex fistula-in-ano. Physical examination and anal ultrasonography provided data on primary track, internal opening, horseshoe extension and the presence of secondary tracks or cavities in a protocol designed specifically for the study. These assessments were subsequently contrasted with operative findings.Results: we included 35 patients, 19 (54.3%) with primary complex anal fistulas and 16 (45.7%) with recurrent fistulas. According to the operative findings, fistulas were classified as high transsphincteric in 28 patients (80%), suprasphincteric in 6 (17.1%) and extrasphincteric in one patient (2.9%), with no differences between groups. Physical examination correctly classified 28 of the 35 fistulous tracks, in contrast to the 32 (91.4%) correctly described on ultrasonography (80%). We did not find any statistically significant differences between the primary and the recurrent fistula groups with regard to sensibility, positive predictive value and accuracy of the anal ultrasonography for any of the parameters studied.Conclusion: the accuracy of anal ultrasonography does not decrease in recurrent complex fistula-in-ano.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.