Background: Vitamin D is an essential prohormone for the normal skeletal and extraskeletal health. Vitamin D deficiency/ insufficiency is an unrecognized epidemic among children and adults worldwide. There are growing data from studies of young children and adolescents in other countries, but a limited information are available regarding the prevalence of this nutritional deficiency/insufficiency among the Nepalese children and adolescents. Thus this study was aimed to find out the prevalence of vitamin D deficiency/insufficiency among children and adolescents, who has attended in Chitwan Medical College (CMC). Methods: This was a retrospective hospital based study in children between 2 months and 19 years of age, conducted in CMC from April 2015 to December 2016. Results: Among 108 total studied, overall 74.1% (80) patients had 25(OH) D levels lower than 30 ng/ml with 27.8% having severe deficiency (< 10 ng/ml), 28.7% deficiency (10-19 ng/ml) and 17.6% insufficiency (20-29 ng/ml) category . The prevalence was found higher in females (95.2%), though the difference in prevalence between sexes was not statistically significant (P -value 0.243). Conclusion: Our study concluded that a high prevalence of low Vitamin D status (deficiency/insufficiency) found among the paediatric population (all paediatric age groups) indicates a need for further national level study to find out the actual prevalence of this nutritional deficiency, as well as the need for vitamin D supplementation to all children and adolescents.
Introduction: Clavicle fractures are the common fractures around the shoulder. Conservative treatment is associated with higher incidence of nonunion. We conducted this study to assess the functional outcome of plating for displaced middle third clavicle fractures. Methods: This prospective study included 60 patients with displaced middle third clavicle fractures from April 2016 to March 2017. Fixation was done with a 3.5 mm reconstruction plate placed at the superior surface of the clavicle. Patients were followed-up for a minimum of one year. Functional outcome was assessed using Constant shoulder score. Results: There were 48 male and 12 female patients with a mean age of 33.17 years (range 18-74 years). The average follow-up period was 17.82 months. All fractures united at an average of 5.35 months. The mean Constant score at final follow-up was 89.12. There were two superficial infections and three implant failures. Conclusion: We conclude that treatment of displaced middle third clavicle fracture with plate gives good results.
Caffey disease is a rare, self limiting condition which usually presents in early infancy. The clinical features include fever, irritability, inflammatory swelling of soft tissue due to acute inflammation of the periosteum and subperiosteal new bone formation. Possible differential diagnoses are osteomyelitis, hypervitaminosis A, scurvy, bone tumours, prolonged use of Prostaglandin E1 (PGE1) and child abuse. Although self-limiting, it can cause diagnostic dilemma leading to delayed diagnosis and unnecessary investigations. Here, we report a case of two month old male infant presenting with painful left scapular mass.
Introduction: Distal radius fractures are the most common fractures in elderly. Unstable fractures are best managed surgically and the results of volar locking plates have been promising. The purpose of this study is to determine the functional outcome of volar locking plates in the treatment of unstable distal radius fractures. Methods: Forty-five patients with 46 unstable distal radius fractures were enrolled for this study, conducted at Chitwan Medical College from September 2016 to April 2017. All patients were treated with a 3.5mm titanium volar locking plate and followed-up for a minimum of one year. The assessment was done using radiological evaluation and Cooney modification of the Green and O’Brien scoring system. Results: Twenty-three men and 22 women with age ranging from 15-75 years (mean 43.22 years) were followed-up for an average of 16.53 months. There were 17 type A fractures (5 A2, 12 A3), 11 type B fractures (3 B1, 1 B2, 7 B3), and 18 type C fractures (4 C1, 12 C2, 2 C3) (AO classification). The mean time for union was 7.96 weeks. Functional outcome using modified Green and O’Brien Score was 20 excellent, 15 good, 7 fair and 4 poor results (76.1% good to excellent results). The overall complication rate was 15.22%. Conclusion: Volar locking plates provide adequate fixation for unstable distal radius fractures with minimal loss of reduction and satisfactory functional outcome.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.