The aim of our study was to evaluate through Finite Elements Analysis (FEA), the stress induced into the abutments and into a metallic bridge by an alimentary bolus of different consistency. Research was carried using the FEA on a model of the bridge with full crowns as retainers in the posterior teeth (34-36), obtained using a contact scanner and computer aided design (CAD) system. We surveyed the stress induced by different food consistency with elasticity modulus between 0 MPa and 60000 MPa. A 6MPa stress was induced by the bridge when the elasticity modulus was equal to 200 MPa. For the maximal value of the elasticity modulus, the stress was 13.68Mpa. The highest values of stresses are registered for the maximal values of the elasticity modulus.
Acrylic resins are frequently used in dentistry for the removable partial or complete denture but, epidemiological studies report that approximately 70% of removable denture wearers suffer from denture stomatitis. Silver nanoparticles (AgNps) incorporation aims to avoid or at least to decrease the microbial colonization over dental materials, but their influence on the mechanical features is still not very well known. A total of 100 heat curing and 100 of self-curing acrylic resin samples were made, and divided into three groups for both resins (ten for each), according to the concentration of AgNPs solution (5%, 10%, and 20% vol.) incorporated into the monomer. One control group without AgNPs for each resin was prepared, as well. The dimensions of the used AgNPs, were 20, 40 and 60 nm. The structural changes were analyzed with Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM). The thermal behavior was evaluated through Differential Scanning Calorimetry (DSC). The results demonstrated that AgNPs incorporation doesn�t induce significant structural and thermal changes in dental resins.
The longevity of dental prostheses depends on the strictness of following the clinical-technological algorithm. The main method of obtaining the metallic dental prostheses is casting, which involves a succession of stages that may produce modifications in the alloy structure, that will lead to alteration of its biological and mechanical behaviour. The modification of some technological parameters influences the internal microstructure and, implicitly, the mechanical properties of the metallic dental prostheses.The paper aims to investigate the influence of cooling rate on the mechanical properties of the titanium moulded pieces. We realized 40 samples divided in four groups consisting of 10 samples each: one group as control, and three test groups. The 30 test samples underwent a thermal treatment of homogenization, represented by a heating process up to 400 �C on 0.1� C per second. The samples were maintained at 400 �C for 2 min , and, after that were cooled at different rate: group 2: 70�C/s, group 3: 30�C/s, and group 4: cooled with an average rate, varying from 30 to 70 �C/s. Group 1 was the control group consisted in 10 samples without thermal treatment. The results showed that mechanical properties of the control group are inferior comparing to the samples submitted to the thermal treatment. Among the three groups of samples that have been thermal treated, the samples that have been cooled at an average rate, varying from 30 to 70 �C/s(group 3), have optimal mechanical properties.
Periodontal diseases ranges from simple gum inflammation to serious disease that consists in major damage to the soft tissue and bone teeth support. Periodontal diseases affects the marginal and apical periodontium and results from the interaction between bacterial biofilm and the host response. To determine the concentrations of MMP-8, as a disease marker, in saliva in prosthetic and nonprosthetic, aggressive (AP) and chronic (CP) periodontitis, doxycycline treated patients. 40 patients were distributed into 3 groups: 12 diagnosed with aggressive (AgP), 18 with chronic (CP) periodontitis. Each of these groups was subdivided into 2 subgroups with and without fixed prosthesis. 10 patients were in the normal group. Matrix metalloproteinase 8 (MMP-8) was evaluated before and after systemic doxycycline (Dox) treatment. mean MMP-8 value into the control group was 0.57 ng/mL with a standard deviation (STD) of 0,094 ng/mL. Highest MMP-8 value was established for the nonprosthesis AgP subgroup, before Dox treatment. The highest reduction in MMP-8 levels (40.8%) was between nonprosthesis AgP before Dox treatment and the same group after Doxycycline treamtent. MMP-8 saliva levels are lower than GCF levels, mostly through a dilution mechanism as previous studies had shown. Our study revealed that saliva MMP-8 level is relible marker for AgP but not for CP. Doxycycline treatment, in terms of lowering MMP-8 levels is most effective in patients that have AP and are also wearing fixed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.