Wine creates a group of oral-tactile stimulations not related to taste or aroma, such as astringency or fullness; better known as mouthfeel. During wine consumption, mouthfeel is affected by ethanol content, phenolic compounds and their interactions with the oral components. Mouthfeel arises through changes in the salivary film when wine is consumed. In order to understand the role of each wine component, eight different model wines with/without ethanol (8%), glycerol (10g/L) and commercial tannins (1g/L) were described using a trained panel. Descriptive analysis techniques were used to train the panel and measure the intensity of the mouthfeel attributes. Alongside, the suitability of different instrumental techniques (rheology, particle size, tribology and microstructure, using Transmission Electron Microscopy (TEM)) to measure wine mouthfeel sensation was investigated. Panelists discriminated samples based on their tactile-related components (ethanol, glycerol and tannins) at the levels found naturally in wine. Higher scores were found for all sensory attributes in the samples containing ethanol. Sensory astringency was associated mainly with the addition of tannins to the wine model and glycerol did not seem to play a discriminating role at the levels found in red wines. Visual viscosity was correlated with instrumental viscosity (R=0.815, p=0.014). Hydrodynamic diameter of saliva showed an increase in presence of tannins (almost 2.5-3-folds). However, presence of ethanol or glycerol decreased hydrodynamic diameter. These results were related with the sensory astringency and earthiness as well as with the formation of nano-complexes as observed by TEM. Rheologically, the most viscous samples were those containing glycerol or tannins. Tribology results showed that at a boundary lubrication regime, differences in traction coefficient lubrication were due by the presence of glycerol. However, no differences in traction coefficients were observed in presence/absence of tannins. It is therefore necessary to use an integrative approach that combines complementary instrumental techniques for mouthfeel perception characterization.
The hip simulator was fully instrumented with a three-electrode electrochemical cell to facilitate monitoring of corrosive degradation. The estimated volume loss from corrosion at the bearing surface was seen to increase by nearly an order of magnitude for both devices, representing as much as 17 % of total degradation. Anodic current transients also displayed near order of magnitude increases in the peak current for both bearing couples. An adverse loading scenario could cause as much as an order of magnitude increase in the metallic ions released into the joint capsule as well as an increased volume of wear debris.
The degradation of Metal-on-Metal (MoM) Total Hip Replacements (THRs) is a complex mix of tribological, corrosive phenomena and their synergistic processes. Previous links between the corrosion of these devices and their sliding conditions over a cycle have been observed in simulator studies instrumented with a three-electrode electrochemical cell. This study further quantifies that link; demonstrating clear repeating periodicity in the anodic current transients of a 28 mm diameter MoM bearing under a standard ISO-14242 walking profile. A simplified 2D model and an expression of the Hamrock-Dowson equation was utilised to estimate the Theoretical Minimum Film Thickness (h min ) over a cycle, which was shown to match closely to the measured anodic current in both shape and magnitude.
Interest in the degradation mechanisms at the modular tapers interfaces has been renewed due to increased reported cases of adverse reactions to metal debris and the appearance of wear and corrosion at the modular tapers interfaces at revision. Over the past two decades, a lot of research has been expended to understand the degradation mechanisms, with two primary implant loading procedures and orientations used consistently across the literature. ASTM F1875-98 is often used as a guide to understand and benchmark the tribocorrosion processes occurring within the modular tapers interface. This article presents a comparison of the two methods outlined in ASTM F1875-98 as well as a critique of the standard considering the current paradigm in pre-clinical assessment of modular tapers.
Taper degradation in Total Hip Replacements (THR) has been identified as a clinical concern, and the degradation occurring at these interfaces has received increased interest in recent years. Wear and corrosion products produced at the taper junction are associated with adverse local tissue responses, leading to early failure and revision surgery. Retrieval and in-vitro studies have found that variations in taper design affect degradation. However, there is a lack of consistent understanding within the literature of what makes a good taper interface. Previous studies assessed different design variations using their global parameters assuming a perfect cone such as: taper length, cone angle and diameters. This study assessed geometrical variations of as-manufactured head and stem tapers and any local deviations from their geometry. The purpose of this study was to provide a greater insight into possible engagement, a key performance influencing parameter predicted by Morse taper connection theory. This was achieved by taking measurements of twelve different commercially available male tapers and six female tapers using a coordinate measurement machine (CMM). The results suggested that engagement is specific to a particular head-stem couple. This is subject to both their micro-scale deviations, superimposed on their macro-scale differences.Differences in cone angles between female and male tapers from the same manufacturer was found to create a predominately proximal contact. However, distally mismatched couples are present in some metal-on-metal head-stem couples. On a local scale, different deviation patterns were observed from the geometry which appeared to be linked to the manufacturing process. Future work will look at using this measurement methodology to fully characterise an optimal modular taper junction for a THR prosthesis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.