Background-Anatomic structures such as the left atrium and the pulmonary veins (PVs) are not delineated by fluoroscopy because there is no contrast differentiation between them and the surrounding anatomy. Representation of an anatomic structure via a 3D model obtained from computed tomography (CT) imaging and subsequent projection of these images over the fluoroscopy system may help in navigation of the mapping and ablation catheter to the appropriate sites during electrophysiology procedures. Methods and Results-In this feasibility study, in vitro experiments were performed with a plastic heart model (phantom) with 2 catheters or radiopaque platinum beads placed in the phantom at the time of CT imaging and fluoroscopy. Subsequently, 20 consecutive patients underwent contrast-enhanced, ECG-gated CT scanning. Left atrial volumes were generated from the reconstructed data at Ϸ75% of the R-R interval during the cardiac cycle. Similarly, the superior vena cava and the coronary sinus were also reconstructed from these images. During the electrophysiology procedure, digital records (cine sequences) were obtained. Using predetermined algorithms, both the phantom model and the patients' 3D left atrial models derived from the CT were registered with projection images of fluoroscopy. Registration was performed with a transformation that linked the superior vena cava and the coronary sinus from the CT model with a catheter placed inside the coronary sinus via the superior vena cava. Registration was successfully accomplished with the plastic phantom and in all 20 patients. Registration accuracy was assessed in the phantom by assessing the overlapping beads seen both in the CT and the fluoroscopy images. The mean registration error was 1.4 mm (range 0.9 to 2.3 mm). Accuracy of the registered images was assessed in patients with recordings from a basket catheter placed sequentially in the superior PVs and by injecting contrast into the PVs to assess overlapping of contrast-filled PVs with the corresponding vessels on the registered images. The images could be calibrated quite accurately. Any rotational error, which was usually minor, could be corrected by rotating the images as needed.
Conclusions-Registration
Under normal conditions, there is little change in the anatomical relationship between the posterior left atrium and the esophagus during the entire cardiac cycle. However, due to the interpatient variability at the esophageal location, identification of esophageal location may help prevent complications during catheter ablation procedures involving the left atrium.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.