Automaticity from extra nodal accessory pathways appears to be rare. We report the case of a man with the WPW syndrome who presented for repeat electrophysiological study and catheter ablation. After successful ablation of a para-Hisian accessory pathway, an isoproterenol challenge produced an accelerated wide complex rhythm that was dissociated from sinus rhythm and matched the previous pattern of maximal preexcitation. This automatic rhythm was transient and dependent on catecholamine administration. One month after successful ablation, an exercise treadmill test (ETT) did not demonstrate any pre-excitation or ectopy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.