This paper describes the principle and performance of FlexRay, a fully programmable illuminator for high NA immersion systems. Sources can be generated on demand, by manipulating an array of mirrors instead of the traditional way of inserting optical elements and changing lens positions. On demand (freeform) source availability allows for reduction in R&D cycle time and shrink in k1. Unlimited tuning allows for better machine to machine matching. FlexRay has been integrated in a 1.35NA TWINSCAN exposure system. We will present data of FlexRay using measured traditional and freeform illumination sources. In addition system performance qualification data on stability, reproducibility and imaging will be shown. The benefit of FlexRay for SMO enabling shrink is demonstrated using an SRAM example.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.