In April 2022, several cases of acute hepatitis of unknown origin were reported in children from 12 countries. In many cases, enteric adenovirus or SARS-CoV-2 and adenovirus coinfection were detected.
Background: Different species of Campylobacter are the most common causes of bacterial gastroenteritis. There are many methods to detect the presence of Campylobacter, including PCR, but it takes about 5-6 hours. Using loop-mediated amplification assay allowed reducing the time of detection and simplifying the procedure at all. Aims: To develop a loop-mediated isothermal amplification assay (LAMP) with fluorescent probe for the diagnosis of campylobacteriosis. Methods: Stool suspensions were prepared and bacterial fractions were separated as in methodological recommendation of Central Research Institute of Epidemiology described. DNA was extracted using AmpliTest RIBO-prep (FSBI SPC FMBA, Russian Federation) according to the manufacturers instruction and detected with AmpliSens OKI-screen-FL" (FBIS CRIE, Russian Federation). Primers and probes were selected in 16S rDNA gene region. Analytical specificity was confirmed on bacterial cultures, analytical sensitivity was assessed using a recombinant plasmid containing the target Campylobacter DNA sequence fragment. LAMP amplification was performed at 65 C for 30 min. Results: An assay for the detection of Campylobacter spp. based on loop-mediated isothermal amplification is developed, the reaction time does not exceed 30 minutes. The analytical sensitivity of the developed technique is comparable to the real-time PCR and is equal to 103 copies / ml, the analytical specificity is 100%. The evaluation of 127 clinical samples, previously characterized by the commercial kit "AmpliSens OKI-screen-FL" (FBIS CRIE, Russian Federation), showed high diagnostic specificity and sensitivity of the developed LAMP-method. No false positive results were found, 108 samples were negative by LAMP and PCR. Campylobacter spp. DNA was detected by the LAMP method in 18 out of 19 PCR-positive samples. One discordant LAMP negative sample can be attributed to the low bacterial load of Campylobacter spp. for a given sample. Conclusions: A method for the rapid detection of Campylobacter spp. loop-mediated isothermal amplification is developed, and its high analytical and diagnostic characteristics have been shown experimentally. Keywords: Gastrointestinal infections, molecular diagnostics, rapid diagnostics, Loop-Mediated Isothermal Amplification (LAMP), Campylobacter spp.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.