PurposeTo investigate central and peripheral corneal endothelial cell density (ECD) in relation to Baerveldt (BV) glaucoma drainage device (GDD) tube corneal (TC) distance.MethodsProspective study of all patients scheduled for glaucoma tube surgery with 36 months follow‐up. A BV GDD was inserted into the anterior chamber (AC). Anterior segment optical coherence tomography (AS‐OCT) scans were made to determine the TC distance. Central and peripheral ECD was measured, preoperatively and at 3, 6, 12, 24 and 36 months postoperatively.ResultsFifty‐three eyes were included [primary open‐angle glaucoma, (n = 13); secondary glaucoma, (n = 30); and primary angle‐closure glaucoma, (n = 10)]. Central ECD significantly decreased during follow‐up, with a mean decrease of 4.54% per year (p < 0.001), and 6.57% in the peripheral quadrant closest to the BV GDD tube (PQC, p < 0.001). In the PQC, a yearly decrease of 1.57% was shown after transiridial tube placement versus 7.43% after placement ‘free’ into the AC (p = 0.006). Endothelial cell (EC) loss was related to TC distance (mean 1.69 mm), with a central loss of 6.20% and 7.25% in the PQC per year with shorter TC distances, versus a central loss of 4.11% and 5.77% in the PQC per year with longer TC distances (outside mean ± 2SD, p < 0.001). A difference in EC loss by glaucoma subtype was not identified.ConclusionThe TC distance is of significant influence on corneal ECD, a shorter TC distance causing more severe EC loss, especially in the PQC. Transiridial placement of the BV GDD tube seems safer than placement ‘free’ into the AC.
Total ocular and corneal aberrations are not comparable when measured with different aberrometers. Hartmann-Shack aberrometers showed the best repeatability for total ocular aberrations and iTrace for corneal aberrations. It would be worthwhile in the future to evaluate aberrometers in patients with more aberrant eyes.
The overall reproducibility of the ICA measurements with the AS-OCT is good in open angles. Inter- and intraobserver variability showed similar mean values of reproducibility between the experts and nonexperts. The wide range of intraobserver variation in the nonexperts suggests that this group should undergo extensive instruction before routinely analyzing AS-OCT images.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.