Changes in protein levels and lipid compositions in algal cells indicate the severity of stress related to toxic concentrations of heavy metals. In this study, the effects of exposure to cadmium and copper on Chlorella vulgaris and its capacity to remove metals were evaluated. The data revealed ion removal activity by microalgae under all treatments and different levels of protein expression after 48 h of exposure. Furthermore, we analyzed lipids contents to characterize them.
Roasted and ground coffee is targeted by fraudulent addiction of products. In this way the determination of contaminants in coffee has economic and nutritional importance. In this study, the coffee adulteration by corn were detected using DSC (differential scanning calorimetry) and FTIR (Fourier transform infrared spectroscopy) coupled to PCA (principal component analysis), and PLS (partial least squares) models. Three different levels of roasted and ground Coffea arabica L. were used to prepare mixtures with roasted and ground corn. The level of adulteration used was between 0.5 to 40% (m/m). It was observed that both DSC and FTIR coupled with PCA are able to discriminate adulterated from unadulterated samples of coffee by corn at levels below 1%. PLS models were built with DSC and FTIR data reaching good correlation between the values of estimated and reference concentrations, with RMSECV (root mean square error of cross-validation) lower than 3.5% for DSC data and 2.7% for FTIR data.
This study presents a comparison of partial least squares (PLS) and multivariate curve resolution (MCR-ALS) in the quantification of polymorphic forms I and II of fexofenadine.HCl in pharmaceutical tablets using near infrared chemical imaging (NIR-CI). The PLS model built using a standard normal variate (SNV) pre-processing method resulted in satisfactory fits between the reference and predicted values, with a root mean square error of prediction (RMSEP) for both polymorphic forms below 1.5% (w/w). The MCR-ALS results were obtained using an augmented matrix and SNV pre-processing method. The lack of fit value for decomposition was 0.13%, the correlation coefficient between the pure spectra and the obtained spectral profiles was 99.94% and the RMSEP was below 6% (w/w). The MCR-ALS model efficiently quantified the polymorphic forms and generated distribution maps; however, the PLS model exhibited better recovery of the concentrations.
A study was carried out to investigate compatibility of amlodipine besylate and olmesartan medoxomil with a variety of pharmaceutical excipients. Both drugs are antihypertensive agents that can be administered alone, in monotherapy, or in pharmaceutical association. The studies were performed using binary and ternary mixtures, and samples were stored for 3 and 6 months at 40°C under 75% relative humidity and dry conditions. For this study, a method based on high-performance liquid chromatography (HPLC) was developed and validated for the simultaneous determination of amlodipine besylate and olmesartan medoxomil in samples from pharmaceutical preformulation studies using diode array detector (DAD) and charged aerosol detector (CAD). The runtime per sample was 10 min with retention time of 7.926 min and 4.408 min for amlodipine and olmesartan, respectively. The validation was performed according to ICH guidelines. The calibration curve presents linear dynamic range from 12 to 250 μg mL−1 for amlodipine and from 25 to 500 μg mL−1 for olmesartan with coefficient of determination (R2 ≥ 0.9908) while repeatability and reproducibility (expressed as relative standard deviation) were lower than 1.0%. The excipients such as corn starch, croscarmellose sodium, magnesium stearate, polyvinyl alcohol, talc, polyvinylpyrrolidone, lactose monohydrate, and polyethylene glycol showed potential incompatibilities after accelerated stability testing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.