Substituted 2-arylbenzothiazoles have emerged in recent years as an important pharmacophore in a number of diagnostic and therapeutic settings. Attractive features of drug candidates based on this benzothiazole scaffold include their synthetic accessibility, and synthetic approaches to 2-arylbenzothiazole-based compounds will be reviewed here. Examples of 2-arylbenzothiazoles endowed with diagnostic/therapeutic activity include the 2-(4-aminophenyl)benzothiazole series, which has a remarkable activity profile in both the potential non-invasive diagnosis of Alzheimer's disease and as antitumour agents.
Head motion occurring during brain PET studies leads to image blurring and to bias in measured local quantities. The objective of this work was to implement a correction method for PET data acquired with the mMR synchronous PET/MR scanner. A list-mode-based motion-correction approach has been designed. The developed rebinner chronologically reads the recorded events from the Siemens list-mode file, applies the estimated geometric transformations, and frames the detected counts into sinograms. The rigid-body motion parameters were estimated from an initial dynamic reconstruction of the PET data. We then optimized the correction forC-Pittsburgh compound B (C-PIB) scans using simulated and actual data with well-controlled motion. An efficient list-mode-based motion correction approach has been implemented, fully optimized, and validated using simulated and actual PET data. The average spatial resolution loss induced by inaccuracies in motion parameter estimates and by the rebinning process was estimated to correspond to a 1-mm increase in full width at half maximum with motion parameters estimated directly from the PET data with a temporal frequency of 20 s. The results show that the rebinner can be safely applied to theC-PIB scans, allowing almost complete removal of motion-induced artifacts. The application of the correction method to a large cohort of C-PIB scans led to the following observations: first, that more than 21% of the scans were affected by motion greater than 10 mm (39% for subjects with Mini-Mental State Examination scores below 20), and second, that the correction led to quantitative changes in Alzheimer-specific cortical regions of up to 30%. The rebinner allows accurate motion correction at a cost of minimal resolution reduction. Application of the correction to a large cohort of C-PIB scans confirmed the necessity of systematically correcting for motion to obtain quantitative results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.