Grit causes problems in water resource recovery facilities (WRRFs): clogging pipes, damaging pumps, and reducing the active volume of aeration tanks and anaerobic digesters by grit accumulation.Grit chambers are built to remove these particles. However, no standardized methodology exists to characterize grit particles for grit chamber design and operation despite the large observed variability in grit composition. Therefore, this paper proposes a combination and adaptation of existing methods to sample and characterize grit particles in view of proper grit chamber design and its modelling to ultimately optimize the efficiency of this important WRRF unit process. Characteristics evaluated included particle size distribution from sieving after different sample pretreatments, organic/inorganic fractions, and density.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.