This paper proposed a 7-level Cascaded H-Bridge Multilevel Inverter (CHBMI) with two diffenrent controller, ie, PID and Artificial Neural Network (ANN) controller to improve the output voltage performance and achieve a lower Total Harmonic Distortion (THD). A PWM generator is connected to the 7-level CHBMI to provide switching of the MOSFET. The reference signal waveform for the PWM generator is set to be sinusoidal to obtain an ideal AC output voltage waveform from the CHBMI. By tuning the PID controller as well as the self-learning abilities of the ANN controller, switching signals towards the CHBMI can be improved. Simulation results from the general CHBMI together with the proposed PID and ANN controller based 7-level CHBMI models will be compared and discussed to verifyl the proposed ANN controller based 7-level CHBMI achieved a lower output voltage THD value with a better sinusoidal output performance.
This paper explores the feasibility of multilevel dual-active bridge-inverter (DABMI) applications for grid-connected applications of a modern Model of Predictive Direct Power Control (MPDPC) based on the conservative power theory (CPT). In the case of unbalanced grid voltages, the objective of the study is to promote continued active and reactive energy in MPDPC without reducing efficiency such as transient response and current harmonics. The nature of the instantaneous p-q theory permits only one out of three control targets to be fulfilled. The proposed control approached directly regulates the instantaneous active and reactive power to achieve three particular control objectives namely sinusoidal and symmetrical grid current, cancelling twice of fundamental grid frequency reactive power ripples, and removing twice grid frequency active power ripple. The techniques of complicated Grid part sequence extraction are unnecessary and improved at no extra expense, as is the case with current MPDPC fault-tolerant approaches. The instantaneous power at the next sampling instant is predicted with the newly developed discrete-time model. Each possible switching state will then be evaluated in the cost function defined until the optimal state which lead to the minimum power errors is determined. In MATLAB/Simulink simulation, the proposed CPT-based MPDPC measures reliability and performance at balanced and unbalanced grid voltages then compared with the conventional and existing MPDPC The proposed method manages to achieve all of three control targets which generates sinusoidal grid currents and attenuates active and reactive power ripple of twice the grid frequency exactly at the same time without losing its critical efficiency including transient reaction and current harmonics.
This paper deal with the problem in speed controller for Indirect Field Oriented Control of Induction Motor. The problem cause decrease performance of Induction Motor where it widely used in high-performance applications. In order decrease the fault of speed induction motor, Takagi-Sugeno type Fuzzy logic control is used as the speed controller. For this, a model of indirect field oriented control of induction motor is built and simulating using MATLAB simulink. Secondly, error of speed and derivative error as the input and change of torque command as the output for speed control is applied in simulation. Lastly, from the simulation result overshoot is zero persent, rise time is 0.4s and settling time is 0.4s. The important data is steady state error is 0.01 percent show that the speed can follow reference speed. From that simulation result illustrate the effectiveness of the proposed approach.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.