Background: This study was conducted to compare dosimetric parameters and dose to specific organs at risk (spinal cord and parotids) between intensity modulated radiation therapy (IMRT) and helical tomotherapy (HT) in head and neck squamous cell carcinomas (HNSCC).Methods: Thirty patients with histologically proven HNSCC were treated with chemo radiotherapy, to a dose of 60-70 Gray in 30-35 fractions. This study consists of two arms; IMRT arm and tomotherapy arm. Fifteen consecutive patients treated under IMRT and 15 patients were treated under helical tomotherapy, along with concurrent chemotherapy. PTV1 encompasses low risk planning target volume (PTV) which receives 50 Gy; PTV2 encompasses intermediate risk PTV which receives 54-60 Gy and PTV3 encompasses high risk PTV which receives 66-70 Gy. After completion of planning, dose to the organs at risk (OARs) and targets, homogeneity index and conformity index were evaluated, and tabulated.Results: On evaluation of plans we found that V95% in PTV1, PTV2 and PTV3 were 91.82%, 96.85% and 90.67% respectively for IMRT and 99.25%, 99.68% and 99.73% respectively for tomotherapy. For PTV3, V110% was 0.11% for IMRT and 0.01% for tomotherapy. Homogeneity index in IMRT arm was 0.285 and it was 0.206 in tomotherapy arm. Conformity index was found to be 1.04 for IMRT plans and 1.06 for tomotherapy plans. When mean dose to contra lateral parotids was evaluated, it was 26.91 Gy in IMRT arm and 25.97 Gy in tomotherapy arm. Max dose to spinal cord was better in tomotherapy (43.07 Gy in IMRT and 34.41 Gy in tomotherapy).Conclusions: There was statistically significant reduction in spinal cord maximum dose and point doses in tomotherapy plans compared to IMRT plans. The decrease in spinal cord dose can increase the tolerance reserve which can be useful in dose escalation or re-irradiation if required. There was also decrease in contra lateral parotid doses (not statistically significant). There was significant improvement in V95% in tomotherapy arm compared to IMRT arm, indicating the significantly superior coverage of target volumes in helical tomotherapy plans compared to IMRT plans. V110% (hot spots) inside the target was very minimal in tomotherapy arm compared to IMRT arm. Conformity index, homogeneity index between two arms were comparable.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.