The combination of advanced radar sensor technology and smart grid has broad prospects. It is meaningful to monitor the respiration and heartbeat of grid employees under resting state through radar sensors to ensure that they are in a healthy working state. Ultra-wideband (UWB) radar sensor is suitable for this application because of its strong penetration ability, high range resolution and low average power consumption. However, due to weak heartbeat amplitude and measurement noise, the accurate measurement of the target heart rate is a challenge. In this paper, singular spectrum analysis (SSA) is proposed to reconstruct the eigenvalues of noisy vital signs to eliminate noise peaks around the heartbeat rate; combined with the variational modal decomposition (VMD), the target vital signs can be extracted with high accuracy. The experiment confirmed that the target vital sign information can be extracted with high accuracy from ten subjects at different distances, which can play an important role in short distance human detection and vital sign monitoring.
In order to achieve higher frequency measurement accuracy, this paper proposed a characteristic pulse detection method of fuzzy area based on the quantized phase processing method of different frequency groups. First, the fuzzy area of the group phase coincidence points continuously moved on the time axis after passing through delay elements. The moving distance, that is, the number of the delay elements was determined by the main clock cycle of the D flip-flop. After that, three groups of phase coincidence detection fuzzy areas in different positions were sent to the digital logic module to extract the edge pulses of the phase coincidence detection fuzzy area. The pulse width is determined by the difference between the clock cycles of the delay elements. The clock cycles of different delay units were adjusted to obtain nanosecond or even picosecond circuit detection resolution. Finally, the pulses generated at the edge of the phase coincidence fuzzy area are taken as the switching signal of the frequency signal counter, so the stability of the gate signal and the accuracy of the gate time measurement are improved. The experimental results show that frequency stability can reach the order of E-13/s. In addition, compared with the traditional measurement method, it is characterized by simple structure, low cost, low noises, and high measurement resolution.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.