Introduction The purpose of the study was to compare the results of gamma value based film analysis according to the used type of self-developer film and software product. Material and methods The films were irradiated with different treatment techniques such as 3D conformal and intensity modulated radiotherapy with static and rotational delivery. Stereotactic plans with conformal and intensity modulated arc techniques, using coplanar and non-coplanar beam setup were also evaluated. The data of irradiated film were compared with the planned planar dose distribution exported from the treatment planning system. Three film analysis software programs were evaluated: PTW Mephysto (PTW), FilmQA Pro (FQP) and radiohromic.com(RC). Both EBT2 and EBT3 types of films were examined. The comparisons of dose distributions were performed with gamma analysis using 10% cut-off level. Results The results of the gamma analysis for larger fields were between 78.3% and 98.3%, 75.7% and 100%, 80.2% and 98.8% with PTW, FQP and RC, respectively. The results of evaluation in case of stereotactic measurements were 76.8%–99.2% for PTW, 95.7%–100% for FQP and 91.2%–99.9% for RC. Conclusions All the three software programs are suitable for calibrating and evaluating films, performing gamma analysis, and can be used for patient specific quality assurance measurements. There is no direct connection between gamma passing rate and absolute accuracy or software quality, it is just a feature of the software. The interpretation of own results has to be defined on an institutional level according to given workflow and preliminary results.
Aim:The aim of this study was to investigate normal tissue sparing through dosimetric parameters of normal tissue volumes using different irradiation techniques for conventional (CFRT) and simultaneously integrated boost (SIB) schedules. Background: Several dose-escalation studies for localized prostate cancer (PCa) have shown advanced biochemical relapse-free (bRFS) rates and also better local control for higher total doses using either CFRT or SIB schedules. Besides the most important organs-at-risk, absorbed dose reduction of other surrounding normal tissues are also preferable. In order to analyse the normal tissue sparing, dosimetric parameters of different normal tissue volumes were examined. Materials and methods: Treatment plans for 15 high risk prostate cancer patients were created using RapidArc (RA), Sliding Window (SW) IMRT and 4-field box (3D-CRT) technique. In order to evaluate normal tissue sparing, the volume of pelvic region was divided into six normal tissue cylinders with 1 cm wall thickness, located in each other. Results: All plans met the criteria of target coverage (V95%>95%). All techniques provided the same results for OARs except 3D-CRT for rectum and bilateral femoral heads. The values of V5, V10 and V15 increased in cases which included RapidArc technique and decreased for V20 and V30. Conclusions: The dosimetric parameters for the cylindrical normal tissue volumes show that using Rap-idArc technique gives equal or slightly better normal tissue sparing and SIB provided the same normal tissue sparing as CFRT planned with RapidArc.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.