Three types of respiratory masks viz N95, non-woven fabric and double layer cotton cloth are being used as an essential inhalation protective measure against COVID-19 by suppressing the entry of respiratory droplets. The ltering e ciency of these masks were tested before and after sterilization using gamma radiation for the two ow rate conditions corresponding normal breath rate (20 lpm) and during sneezing/coughing (90 lpm). Sterilization is carried out using a gamma irradiator containing Co-60 source for the two dose exposures viz. 15kGy and 25kGy. The ltering e ciency for surgical (non-woven fabric) and double layer cotton cloth mask is found to vary from 18% to 22% for the cumulative particle of size ≥ 0.3µm in both un-irradiated and irradiated condition.The ltration e ciency of N95 mask is found to be reduced to 70% for the most penetrating particle size (0.3 µm) with the ow rate of 20 lpm and further reduced for particles in the range of 0.1 and 0.2µm with ow rate of 90 lpm. The reduction in e ciency after gamma sterilization is associated with reduction of electrostatic interaction of lter medium with particles laden in the air stream.Even with reduced ltering e ciency due to gamma sterilization, the N95 masks are much superior than the surgical and cloth masks.Instead of disposing N95 mask after single use, they can be reused a few times as N70 mask during this pandemic crisis after sterilization using gamma radiation.
Summary Background There is a worldwide shortage of medical-grade face masks. Donning masks can play an important role in curbing the spread of SARS-CoV-2. Aim To conclude whether there is an effective mask for the population to wear in public that could easily be made during a medical face mask shortage using readily available materials. Methods We determined the effectiveness of readily available materials and models for making a face mask. The outcomes were compared with N95/FFP2/KN95 masks that entered the Netherlands in April–May 2020. Masks were tested to determine whether they filtered a minimum of 35% of 0.3-μm particles, are hydrophobic, seal on the face, are breathable, and can be washed. Findings Fourteen of the 25 (combinations of) materials filtered at least 35% of 0.3-μm particles. Four of the materials proved hydrophobic, all commercially manufactured filters. Two models sealed the face. Twenty-two of the 25 materials were breathable at <0.7 mbar. None of the hydrophobic materials stayed intact after washing. Conclusions It would be possible to reduce the reproduction rate of SARS-CoV-2 from 2.4 to below one if 39% of the population would wear a mask made from ePM₁ 85% commercially manufactured filter fabric and in a duckbill form. This mask performs better than 80% of the imported N95/FFP2/KN95 masks and provides a better fit than a surgical mask. Two layers of quilt fabric with a household paper towel as filter is also a viable choice for protecting the user and the environment.
The optimal revascularization strategy, percutaneous coronary intervention (PCI) or coronary artery bypass graft surgery (CABG), for patients with multivessel coronary artery disease (MVD) remains controversial. The aim of the present study was to compare the long-term outcomes after selective PCI of only hemodynamically significant lesions (fractional flow reserve, or FFR < 0.75) to CABG of all stenoses in patients with MVD. In 150 patients with MVD referred for CABG, FFR was determined in 381 coronary arteries considered for bypass grafting. If the FFR was less than 0.75 in three vessels or in two vessels including the proximal left anterior descending (LAD) artery, CABG was performed (CABG group). If only one or two vessels were physiologically significant (not including the proximal LAD), PCI of those lesions was performed (PCI group). Of the 150 patients, 87 fulfilled the criteria for CABG and 63 for PCI. There were no significant differences in the angiographic or other baseline characteristics between the two groups. At 2-year follow-up, no differences were seen in adverse events, including repeat revascularization (event-free survival 74% in the CABG group and 72% in the PCI group). A similar number of patients were free from angina (84% in the CABG group and 82% in the PCI group). Importantly, the results in both groups were as good as the surgical groups in previous studies comparing PCI and CABG in MVD. In patients with multivessel disease, PCI in those with one or two hemodynamically significant lesions as identified by an FFR < 0.75 yields a similar favorable outcome as CABG in those with three or more culprit lesions despite a similar angiographic extent of disease.
ObjectiveThere are widespread shortages of personal protective equipment as a result of the COVID-19 pandemic. Reprocessing filtering facepiece particle (FFP)-type respirators may provide an alternative solution in keeping healthcare professionals safe.DesignProspective, bench-to-bedside.SettingA primary care-based study using FFP-2 respirators without exhalation valve (3M Aura 1862+ (20 samples), Maco Pharma ZZM002 (14 samples)), FFP-2 respirators with valve (3M Aura 9322+ (six samples) and San Huei 2920V (16 samples)) and valved FFP type 3 respirators (Safe Worker 1016 (10 samples)).InterventionsAll masks were reprocessed using a medical autoclave (17 min at 121°C with 34 min total cycle time) and subsequently tested up to three times whether these respirators retained their integrity (seal check and pressure drop) and ability to filter small particles (0.3–5.0 µm) in the laboratory using a particle penetration test.ResultsWe tested 33 respirators and 66 samples for filter capacity. All FFP-2 respirators retained their shape, whereas half of the decontaminated FFP-3 respirators showed deformities and failed the seal check. The filtering capacity of the 3M Aura 1862 was best retained after one, two and three decontamination cycles (0.3 µm: 99.3%±0.3% (new) vs 97.0±1.3, 94.2±1.3% or 94.4±1.6; p<0.001). Of the other FFP-2 respirators, the San Huei 2920 V had 95.5%±0.7% at baseline vs 92.3%±1.7% vs 90.0±0.7 after one-time and two-time decontaminations, respectively (p<0.001). The tested FFP-3 respirator (Safe Worker 1016) had a filter capacity of 96.5%±0.7% at baseline and 60.3%±5.7% after one-time decontamination (p<0.001). Breathing and pressure resistance tests indicated no relevant pressure changes between respirators that were used once, twice or thrice.ConclusionThis small single-centre study shows that selected FFP-2 respirators may be reprocessed for use in primary care, as the tested masks retain their shape, ability to retain particles and breathing comfort after decontamination using a medical autoclave.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.