In this study, three desalination exergy analysis models including the Cerci et al. model (Model A), Drioli et al. model (Model B) and electrolyte solution model (Model C), were developed on an existing reverse osmosis (RO) desalination plant in Oman (Plant ALG). A modified ultrapure water (UPW) unit fed by Plant ALG has also been proposed (Plant A) based on the technology used in a UPW unit operated under the climate of Europe and fed by European river water (Plant B). The most suitable exergy model for characterizing the proposed UPW production plant was used. Model C was found to be the most proper model among its counterparts. It reflected the electrolytic behavior of the relevant streams and considered as the appropriate model. The major exergy destruction sites were also identified, and the exergy efficiency was calculated. The electro-de-ionization (EDI) and the RO unit were the highest exergy destructive components in Plant A.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.