In the present study, the performance of concrete sandwich panel against fire and axial load has been considered. A finite element model of a sandwich wall is presented and evaluated the performance under different temperature (200, 400, 600 °C. The ratio of width, thickness and length of wall are constant and the axial load enters on the top of wall. The maximum displacement and stress in different models shows the capacity of wall is increased at high temperature. The displacement has dramatically increased at temperature loading of 800 °C and it has gained which shows poor efficiency of wall at high temperatures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.