The main categories of solar water heating systems (SWHSs) are the thermosyphon and the forced circulation (FC). This paper presents an experiment carried out with the aim to compare the energy performance of the FC with a thermosyphon SHWS. Identical SWHSs were installed side by side at the University of West Attica in Athens, Greece. Domestic hot water load was applied to both systems via a microcontroller-based dispensing unit which mimics the demand profile. The trial period comprised the last two months of spring (April and May). For the first law assessment, two energy indicators were utilized: the solar fraction (SF) and the thermal efficiency of the system (ηth). On days with distinctive weather conditions, both systems obtained approximately equal SF and ηth values, without a specific preference between the ambient conditions and the type of SWHS. Regarding a four-day nonstop operation, the FC overperformed the thermosyphon system at both energy indicators. Namely, for the FC and the thermosyphon SWHS, the SF was calculated to be 0.62 and 0.48, and the ηth was 68.2% and 53.3%, respectively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.