Dexmedetomidine is a centrally acting alpha-2 adrenergic agonist that is currently approved by the US Food and Drug Administration for short-term use (< or = 24 h) to provide sedation in adults in the ICU. This drug has been shown to be efficacious in adult medical and surgical patients in providing sedation, anxiolysis, and analgesia. Dexmedetomidine has been associated with rapid onset and offset, hemodynamic stability, and a natural, sleep-like state in mechanically ventilated adults. To date, there are few publications of the use of this drug in children, and prolonged infusion has not been described. We report our use of dexmedetomidine in a child during a 4-day period of mechanical ventilation following tracheal reconstruction for subglottic stenosis.
Monitoring blood loss is important for management of surgical patients. This study reviews a device (Triton) that uses computer analysis of a photograph to estimate hemoglobin (Hb) mass present on surgical sponges. The device essentially does what a clinician does when trying to make a visual estimation of blood loss by looking at a sponge, albeit with less subjective variation. The performance of the Triton system is reported upon in during real-time use in surgical procedures. The cumulative Hb losses estimated using the Triton system for 50 enrolled patients were compared with reference Hb measurements during the first quarter, half, three-quarters and full duration of the surgery. Additionally, the estimated blood loss (EBL) was calculated using the Triton measured Hb loss and compared with values obtained from both visual estimation and gravimetric measurements. Hb loss measured by Triton correlated with the reference method across the four measurement intervals. Bias remained low and increased from 0.1 g in the first quarter to 3.7 g at case completion. The limits of agreement remained narrow and increased proportionally from the beginning to the end of the cases, reaching a maximum range of -15.3 to 22.7 g. The median (IQR) difference of EBL derived from the Triton system, gravimetric method and visual estimation versus the reference value were 13 (74), 389 (287), and 4 (230) mL, respectively. Use of the Triton system to measure Hb loss in real-time during surgery is feasible and accurate.
The Triton Canister System was able to measure the Hb mass reliably with clinically acceptable accuracy in reconstituted blood samples representing a wide range of Hb concentrations, dilutions, hemolysis, and ambient lighting settings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.