This paper reports on 54 biaxial-loading tests on fiber glass-epoxy laminates of three lamination schemes: parallel ply, cross ply, and quasi-isotropic. The tests were conducted on a specially designed fixture using a cable-pulley system in conjunction with a universal testing machine. The loadings were biaxial tension with 1:1 and 1:2 principal-load ratios. The contours of the reduced-thickness test sections of the flat specimens were designed to achieve a uniform-stress field.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.