The flow field was measured near the inlet and the outlet of an axial flow inducer with shrouded and unshrouded configurations combined with a centrifugal pump. Investigations were conducted using a five-hole probe for several flow rates. The shroud induces a counterrotating flow at the inlet and a blockage effect at the outlet in the region of the tip and for all flow rates. The radial distribution of losses keeps the same shape in both configurations, however, the loss level is higher with the shroud, giving a lower efficiency for the combined inducer-impeller configuration. Effects of shrouded inducer on part load instability are not clear and deserve more research, which is in progress.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.