This paper presents the analysis of the equivalent 10-Hz voltage flicker measurement ( V 10 ) based on the IEC flickermeter standard. The V 10 method has been employed to evaluate voltage flicker for more than two decades in several Asian countries and not been updated since 1978. Therefore, a careful inspection from various aspects was made against the V 10 method. The results uncover the deficiencies in the reliability of the V 10 method for voltage flicker measurement.Index Terms-Voltage flicker, IEC flickermeter.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.