We evaluated histologically samples of synovial tissue from the knees of 50 patients with rheumatoid arthritis (RA). The samples were taken during revision for aseptic loosening. The findings were compared with those in 64 knees with osteoarthritis (OA) and aseptic loosening and in 18 knees with RA without loosening. The last group had been revised because of failure of the inlay or the coupling system of a constrained prosthesis. All the patients had had a total ventral synovectomy before implantation of the primary prosthesis. In all three groups a foreign-body reaction and lymphocellular infiltration were seen in more than 80% of the tissue samples. Deposits of fibrin were observed in about one-third to one-half of the knees in all groups. Typical signs of the reactivation of RA such as rheumatoid necrosis and/or proliferation of synovial stromal cells were found in 26% of knees with RA and loosening, but not in those with OA and loosening and in those with RA without loosening. Our findings show that reactivation of rheumatoid synovitis occurs after total knee replacement and may be a cofactor in aseptic loosening in patients with RA.
The thrust plate prosthesis is an implant with metaphyseal fixation to the proximal femur, which leaves the diaphyseal bone untouched. Therefore, this implant is preferred in younger patients. It is dependent on good bone quality in the proximal femur. Because the bone quality is reduced in patients with polyarthritis, this kind of endoprosthesis may have a higher failure rate than conventional stemmed endoprostheses in these patients. Therefore, in patients with polyarthritis, even short- and medium-term results of the thrust plate prosthesis should be analyzed. In all, 47 thrust plate prostheses were implanted in 42 patients with polyarthritis (29 with rheumatoid arthritis, 6 with juvenile chronic arthritis, and 7 with spondylarthritis) and followed prospectively. The average age at operation was 40.8+/-10.7 years. Each patient was clinically and radiologically examined preoperatively, 3 and 6 months after the operation, and at the end of each postoperative year. The mean follow-up was 26.1+/-10.7 months. The clinical findings were evaluated using the Harris hip score. Radiologically, 8 different zones of the thrust plate prosthesis were analyzed for radiolucencies. During the 1st year, the Harris hip score rose continuously from the preoperative average of 42.4+/-6.5 points to 78.8+/-10.3 points 3 months postoperatively, 82.3+/-9.8 points 6 months postoperatively, and 86.8+/-10.1 points 1 year after the operation. The subsequent examinations showed Harris hip score remained at the same level. Five patients (5 joints, 10.6%) had to undergo a revision of the thrust plate prosthesis due to aseptic loosening in 3 and septic loosening in 2. Six prostheses (12.6%) showed radiolucencies, mostly below the thrust plate in zones 1 and 2. Two of them were certainly radiologically loose, which raised the failure rate to 7 of 47 (14.8%). The thrust plate prosthesis improves function and alleviates pain in patients with polyarthritis to a satisfactory degree. Concerning the failure rate, this type seems to yield slightly worse results than cementless stemmed endoprostheses in the same patient group. Due to the preservation of the diaphyseal bone of the femur and the possibility of an unproblematic change to a stemmed endoprosthesis, the thrust plate prosthesis can be recommended for younger patients with polyarthritis.
The presented study indicates that complete restoration of range of motion after rotational knee arthroplasty may not necessarily be restored at discharge.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.