Background: Ankle joint dorsiflexion range of motion is essential to normal gait. Ankle equinus has been implicated in a number of foot and ankle pathologies included Achilles tendonitis, plantar fasciitis, ankle injury, forefoot pain, and foot ulceration. Reliable measurement of ankle joint dorsiflexion range of motion, both clinically and in a research setting, is important. Methods: The primary aim of this study was to investigate the intertester reliability of an innovative device for measuring ankle joint dorsiflexion range of motion. A total of 31 (n = 31) participants volunteered to take part in this study. A paired t-test was performed to assess for systematic differences between the mean measures of each rater. Intertester reliability was evaluated using the intraclass correlation coefficient (ICC) and their 95% confidence intervals. Results: A paired t-test demonstrated that the mean ankle joint dorsiflexion range of motion did not significantly differ between raters. The ankle joint ROM mean for rater 1 was 4.65 SD (3.71) and rater 2 was 4.67 SD (3.91). Intertester reliability for the use of the Dorsi-Meter was excellent and demonstrated a very narrow range of error. The ICC (95%CI) was 0.991 (0.980 to 0.995) the SEM (in degrees) was 0.07, the MDC95, in degrees was 0.19 and 95% LOA, degrees was –1.49 to 1.46. Conclusions: We found the intertester reliability of the Dorsi-Meter to demonstrate higher levels of intertester reliability compared to previous studies investigating other devices. We reported the MDC values to provide an estimate of the smallest amount of change in the ankle joint dorsiflexion range of motion that must be achieved to reflect a true change, outside the error of the test. The Dorsi-Meter has been established as an appropriate reliable device to measure ankle joint dorsiflexion for clinicians and researchers with very small minimal detectable change and limits of agreement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.