The aim of this study was to compare the efficacy and safety profile of XEN microstent implantation with trabeculectomy (TET) in a comparable group of open-angle glaucoma cases in a retrospective, monocentric, single-surgeon setting. Each treatment group consisted of 100 eyes of 100 patients. At regular follow-up visits during the first 12 months after surgery, the following assessments were conducted and compared: intraocular pressure (IOP), number of IOP-lowering medications applied, best-corrected visual acuity (BCVA) and visual field testing. In both groups mean IOP was significantly reduced (p < 0.001). Mean IOP dropped from 24.8 ± 7.8 to 14.8 ± 4.0 mmHg in the TET and from 24.5 ± 6.7 to 16.6 ± 4.8 mmHg in the XEN group. The number of active compounds in the prescribed medication dropped from 3.3 ± 1.2 to 1.3 ± 1.4 in the TET and from 3.0 ± 1.1 to 1.4 ± 1.5 in the XEN group. BCVA and mean defect of static automated perimetry did not show a change of statistical significance in either group. Complications were more frequent after TET (p = 0.005) while postoperative needling was more frequent in the XEN group (p = 0.021). TET and XEN led to a significant reduction of IOP and IOP-lowering medication, while BCVA and visual field indices remained mostly unaltered over a 12-month postsurgical follow-up.
Background The aim of this retrospective study was to compare the efficacy and safety profile of a single XEN-microstent in different types of primary and secondary open angle glaucoma. Methods A single XEN microstent was implanted in patients with primary open-angle glaucoma (POAG), normal-tension glaucoma (NTG), pseudoexfoliation glaucoma (PEX) and secondary glaucoma (Sec.Gl). The intraocular pressure (IOP), the active substances of the applied IOP-lowering drugs, the best corrected visual acuity (BCVA) and the mean deviation (MD) of the perimetry were measured at baseline and at regular follow-ups, scheduled at 2 days and 1, 3, 6 and 12 months after surgery. Results 153 eyes were included in this analysis. 113 eyes were affected by POAG (74%), 5 eyes by NTG (3%), 22 eyes by PEX (14%) and 13 eyes by Sec. Gl (9%). Mean IOP decreased in all treatment groups during the 12 months of follow-up (complete group: 23.9 ± 7.4 to 15.4 ± 5.1 mmHg (p < 0.01); POAG: 22.8 ± 6.5 to 15.1 ± 4.6 mmHg (p < 0.01); NTG: 16.6 ± 3.4 to 11.6 ± 2.2 mmHg (p < 0.05); PEX: 28.0 ± 7.9 to 17.1 ± 6.6 mmHg (p < 0.01); Sec.Gl: 28.9 ± 13.9 to 15.5 ± 6.9 mmHg (p < 0.05)). In the 153 eyes the average number of IOP-lowering drugs applied decreased from 2.6 ± 1.2 to 0.8 ± 1.3 12 months after surgery (p < 0.01). BCVA and mean deviation of automated standard perimetry remained stable in all groups during follow-up. Conclusion As in eyes suffering from POAG, IOP and number of IOP-lowering drugs applied can be effectively reduced by XEN implantation in eyes suffering from NTG, PEX and secondary glaucoma while leaving BCVA and visual field unchanged. Trial registration Trial was registered at DRKS (registration number: DRKS00020800, Registered 25.February 2020 - Retrospectively registered).
The aim of this study was to compare the efficacy of trabeculectomy (TE), single XEN microstent implantation (solo XEN) or combined XEN implantation and cataract surgery (combined XEN) in primary open-angle glaucoma cases, naïve to prior surgical treatment, using a monocentric retrospective comparative cohort study. Intraocular pressure (IOP) and the number of IOP-lowering drugs (Meds) were monitored during the first 24 months after surgery. Further disease progression was monitored using peripapillary retinal nerve fiber layer (RNFL) thickness examinations using spectral domain optical coherence tomography (OCT) as well as visual acuity (VA) and visual field (VF) tests. In the TE group (52 eyes), the mean IOP decreased from 24.9 ± 5.9 to 13.9 ± 4.2 mmHg (p < 0.001) and Meds decreased from 3.2 ± 1.2 to 0.5 ± 1.1 (p < 0.001). In the solo XEN (38 eyes) and the combined XEN groups, the mean IOP decreased from 24.1 ± 4.7 to 15.7 ± 3.0 mmHg (p < 0.001) and 25.4 ± 5.6 to 14.7 ± 3.2 mmHg (p < 0.001), while Meds decreased from 3.3 ± 0.8 to 0.8 ± 1.2 (p < 0.001) and 2.7 ± 1.2 to 0.4 ± 1.0 (p < 0.001), respectively. The VF and VA indices showed no sign of further deterioration, the RNFL thickness further decreased in all treatment groups after surgery. TE and XEN led to comparable reductions in IOP and Meds. Although the VA and VF indices remained unaltered, the RNFL thickness continuously decreased in all treatment groups during the 24-month follow-up.
Malignant melanomas are characterized by heterogeneity and asymmetry as well as by a higher density of blood vessels than benign pigmented tumours. The aim of this study was to evaluate the benefit of high-resolution laser Doppler perfusion imaging (LDPI) in the differential diagnosis of pigmented skin tumours. One-hundred-and-eighty-nine patients were examined with the LDPI, 22 with malignant melanomas, 39 with clinically suspicious dysplastic melanocytic naevi and 27 with basal cell carcinomas. Following examination, the tumours were excised and examined histologically. A control group of 101 melanocytic naevi showed clinically and, with epiluminescence microscopy, definitely benign criteria. These naevi were not excised. In malignant melanomas there was a 3.6+/-1.5 times higher perfusion than in healthy skin. The corresponding figures for clinically suspicious melanocytic naevi and basal cell carcinomas were 2.2+/-1.1 and 2.0+/-0.7, respectively. The increase in flow in malignant melanomas was significantly higher than in clinically suspicious melanocytic naevi and basal cell carcinomas (p < 0.001). All malignant melanomas showed at least 1.8 times higher flow values than healthy skin. When this value is taken as the basis for the diagnosis "benign or malignant", the LDPI proved a sensitivity of 100% and a specificity of 85%. If only the distinction between malignant melanomas and clinically suspicious naevi is considered, the specificity is reduced to 48%. There was no correlation between tumour thickness and increase in the mean perfusion of malignant melanomas (r = 0.14; p = 0.5). High-resolution LDPI can be used as an additional automatic screening method.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.