Quantitative NMRI and (31)P NMRS indices are reported in the forearms of 24 patients with Duchenne muscular dystrophy (DMD) (6-18 years, 14 non-ambulant) amenable to exon 53 skipping therapy and in 12 age-matched male controls (CONT). Examinations carried out at 3 T comprised multi-slice 17-echo measurements of muscle water T2 and heterogeneity, three-point Dixon imaging of fat fraction in flexor and extensor muscles (FLEX, EXT), and non-localised spectroscopy of phosphate metabolites. We studied four imaging indices, eight metabolic ratios combining ATP, phosphocreatine, phosphomonoesters and phosphodiesters, the cytosolic inorganic phosphate (Pia ) and an alkaline (Pib) pool present in dystrophic muscle, and average pH. All indices differed between DMD and CONT, except for muscle water T2 . Measurements were outside the 95th percentile of age-matched CONT values in over 65% of cases for percentage fat signal (%F), and in 78-100% of cases for all spectroscopic indices. T2 was elevated in one-third of FLEX measurements, whereas %pixels > 39 ms and T2 heterogeneity were abnormal in one-half of the examinations. The FLEX muscles had higher fat infiltration and T2 than EXT muscle groups. All indices, except pH, correlated with patient age, although the correlation was negative for T2 . However, in non-ambulant patients, the correlation with years since loss of ambulation was stronger than the correlation with age, and the slope of evolution per year was steeper after loss of ambulation. All indices except Pi/gATP differed between ambulant and non-ambulant patients; however, T2 and %pixels > 39 ms were highest in ambulant patients, possibly owing to the greater extent of inflammatory processes earlier in the disease. All other indices were worse in non-ambulant subjects. Quantitative measurements obtained from patients at different disease stages covered a broad range of abnormalities that evolved with the disease, and metabolic indices were up to 10-fold above normal from the onset, thus establishing a variety of potential markers for future therapy.
In the present work, the NMR properties of perfluorooctylbromide are revisited to derive a high-sensitivity fluorine MRI strategy. It is shown that the harmful effects of J-coupling can be eliminated by carefully choosing the bandwidth of the 180°pulses in a spin-echo sequence. The T 2 of the CF 3 resonance of the molecule is measured using a multispin-echo sequence and shown to dramatically depend on the interpulse delay. Following these observations, an optimized multispinecho imaging sequence is derived and compared with short TE/pulse repetition time gradient echo and chemical shift imaging sequences. The unparalleled sensitivity yielded by the multispin-echo sequence is promising for future applications, in particular for targeted contrast agents such as perfluorooctylbromide nanoparticles.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.